Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
457
matching recommendationsNAICS | 332119 | Metal Crown, Closure, and Other Metal Stamping (except Automotive) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0362 # 07 Y:2019 | 07 | 2019 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $1,481 | $185 | Implemented |
MI0362 # 08 Y:2019 | 08 | 2019 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,148 | $1,126 | Implemented |
MI0362 # 09 Y:2019 | 09 | 2019 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,147 | $1,090 | Implemented |
MI0362 # 10 Y:2019 | 10 | 2019 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $288 | $187 | Implemented |
LE0456 # 01 Y:2018 | 01 | 2018 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $7,810 | $36 | Implemented |
LE0456 # 02 Y:2018 | 02 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,319 | $2,000 | Not Implemented |
LE0456 # 03 Y:2018 | 03 | 2018 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,140 | $3,500 | Implemented |
LE0456 # 04 Y:2018 | 04 | 2018 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $14,979 | $50,000 | Implemented |
LE0456 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $783 | $3,200 | Implemented |
LE0456 # 06 Y:2018 | 06 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,041 | $40,000 | Implemented |
TT0202 # 07 Y:2017 | 07 | 2017 | INSTALL TIMERS AND/OR THERMOSTATS | $197 | $100 | Implemented |
TT0202 # 06 Y:2017 | 06 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $403 | $678 | Implemented |
TT0202 # 05 Y:2017 | 05 | 2017 | UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS | $3,800 | $1,200 | Not Implemented |
TT0202 # 04 Y:2017 | 04 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $11,774 | $40,000 | Not Implemented |
TT0202 # 03 Y:2017 | 03 | 2017 | INSTALL OCCUPANCY SENSORS | $16,093 | $1,430 | Implemented |
TT0202 # 02 Y:2017 | 02 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $37,949 | $3,000 | Not Implemented |
TT0202 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $47,716 | $83,867 | Implemented |
UK1702 # 01 Y:2017 | 01 | 2017 | OPTIMIZE PLANT POWER FACTOR | $14,192 | $23,388 | Not Implemented |
UK1702 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,889 | $28,344 | Not Implemented |
UK1702 # 03 Y:2017 | 03 | 2017 | INSTALL OCCUPANCY SENSORS | $1,545 | $1,527 | Not Implemented |
UK1702 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $302 | $110 | Not Implemented |
UK1702 # 05 Y:2017 | 05 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,763 | $5,000 | Not Implemented |
UK1702 # 06 Y:2017 | 06 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,044 | $0 | Not Implemented |
UK1702 # 07 Y:2017 | 07 | 2017 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,290 | $250 | Not Implemented |
UK1702 # 08 Y:2017 | 08 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,198 | $9,640 | Not Implemented |