Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

208

matching recommendations
Reset
NAICS 3366 Ship and Boat Building
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0206 # 05 Y:2011 05 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,064 $1,320 Implemented
MI0206 # 06 Y:2011 06 2011 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,757 $2,400 Implemented
MI0206 # 07 Y:2011 07 2011 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $2,108 $4,771 Implemented
MI0200 # 01 Y:2011 01 2011 TURN OFF EQUIPMENT WHEN NOT IN USE $7,552 $4,960 Implemented
MI0200 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,382 $17,910 Implemented
MI0200 # 03 Y:2011 03 2011 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $4,945 $2,000 Implemented
MI0200 # 04 Y:2011 04 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,155 $1,210 Implemented
MI0200 # 05 Y:2011 05 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,326 $40 Implemented
MI0195 # 02 Y:2010 02 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $50,578 $6,600 Implemented
MI0195 # 03 Y:2010 03 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,044 $1,210 Implemented
MI0195 # 04 Y:2010 04 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $8,854 $2,300 Implemented
MI0195 # 05 Y:2010 05 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,905 $40 Implemented
LL0315 # 01 Y:2009 01 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,024 $4,200 Implemented
LL0315 # 02 Y:2009 02 2009 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,718 $300 Implemented
LL0315 # 05 Y:2009 05 2009 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $193 $1,020 Implemented
LL0300 # 01 Y:2008 01 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $53,924 $44,605 Implemented
LL0300 # 04 Y:2008 04 2008 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,002 $750 Implemented
LL0299 # 01 Y:2008 01 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $209,418 $131,055 Implemented
LL0299 # 03 Y:2008 03 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $22,556 $11,220 Implemented
LL0299 # 07 Y:2008 07 2008 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,718 $2,520 Implemented
MS0324 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,347 $19,752 Implemented
MS0324 # 02 Y:2008 02 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,635 $343 Implemented
UW0007 # 01 Y:2007 01 2007 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $15,370 $62,800 Implemented
UW0007 # 04 Y:2007 04 2007 INSTALL OCCUPANCY SENSORS $98 $355 Implemented
UF0405 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $47,407 $51,387 Implemented