Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
129
matching recommendationsNAICS | 3371 | Household and Institutional Furniture and Kitchen Cabinet Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0374 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,046 | $52,243 | Implemented |
SD0374 # 04 Y:2005 | 04 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,982 | $220 | Implemented |
SD0374 # 05 Y:2005 | 05 | 2005 | COVER OPEN TANKS | $2,000 | $4,500 | Not Implemented |
SD0374 # 02 Y:2005 | 02 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,927 | $7,500 | Implemented |
SD0374 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,769 | $140 | Implemented |
SD0374 # 01 Y:2005 | 01 | 2005 | INSTALL AN UNINTERUPTABLE POWER SUPPLY | $27,800 | $0 | Not Implemented |
SD0374 # 06 Y:2005 | 06 | 2005 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $688 | $350 | Implemented |
NC0326 # 01 Y:2005 | 01 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $18,944 | $2,000 | Not Implemented |
NC0326 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,368 | $0 | Implemented |
NC0326 # 02 Y:2005 | 02 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,606 | $5,000 | Implemented |
NC0326 # 05 Y:2005 | 05 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $3,139 | $900 | Implemented |
NC0326 # 03 Y:2005 | 03 | 2005 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $6,834 | $10,100 | Not Implemented |
NC0326 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,112 | $50 | Implemented |
NC0326 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $766 | $503 | Implemented |
NC0326 # 08 Y:2005 | 08 | 2005 | IMPROVE SPACE COMFORT CONDITIONING | $800 | $350 | Implemented |
NC0327 # 04 Y:2005 | 04 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $56 | $83 | Implemented |
NC0327 # 01 Y:2005 | 01 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,743 | $100 | Implemented |
NC0327 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $595 | $200 | Implemented |
NC0327 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $661 | $0 | Implemented |
NC0327 # 06 Y:2005 | 06 | 2005 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $1,266 | $2,312 | Not Implemented |
NC0327 # 07 Y:2005 | 07 | 2005 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,000 | $1,000 | Implemented |
NC0327 # 05 Y:2005 | 05 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $71 | $38 | Implemented |
NC0327 # 03 Y:2005 | 03 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $410 | $820 | Implemented |
NC0327 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $331 | $300 | Not Implemented |
NC0327 # 10 Y:2005 | 10 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $651 | $1,251 | Implemented |