IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

46

matching recommendations
Reset
NAICS 3371 Household and Institutional Furniture and Kitchen Cabinet Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0719 # 06 Y:2016 06 2016 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $700 $760 Implemented
AM0719 # 07 Y:2016 07 2016 KEEP LAMPS AND REFLECTORS CLEAN $390 $57 Implemented
AM0719 # 05 Y:2016 05 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $840 $10 Implemented
AM0719 # 04 Y:2016 04 2016 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $4,440 $2,000 Implemented
AM0719 # 02 Y:2016 02 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,680 $41,400 Implemented
AM0719 # 03 Y:2016 03 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,110 $6,410 Implemented
AM0719 # 01 Y:2016 01 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,350 $1,000 Implemented
AM0719 # 08 Y:2016 08 2016 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $250 $0 Not Implemented
NC0570 # 02 Y:2016 02 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $497 $606 Implemented
NC0570 # 01 Y:2016 01 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,102 $41,992 Implemented
NC0570 # 07 Y:2016 07 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $266 $100 Not Implemented
NC0570 # 08 Y:2016 08 2016 DEVELOP A REPAIR/REPLACE POLICY $1,911 $5,685 Not Implemented
NC0570 # 03 Y:2016 03 2016 INSTALL OCCUPANCY SENSORS $362 $400 Implemented
NC0570 # 05 Y:2016 05 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $416 $200 Implemented
NC0570 # 06 Y:2016 06 2016 TURN OFF EQUIPMENT WHEN NOT IN USE $480 $1,600 Not Implemented
NC0570 # 04 Y:2016 04 2016 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,219 $180 Not Implemented
OK0944 # 02 Y:2016 02 2016 INSTALL OCCUPANCY SENSORS $366 $835 Not Implemented
OK0944 # 04 Y:2016 04 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,222 $1,107 Implemented
OK0944 # 03 Y:2016 03 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,324 $18,000 Not Implemented
OK0944 # 05 Y:2016 05 2016 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $10,916 $0 Not Implemented
OK0944 # 01 Y:2016 01 2016 INSTALL OCCUPANCY SENSORS $914 $1,425 Not Implemented
UA0163 # 01 Y:2016 01 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $42,679 $9,795 Implemented
UA0163 # 05 Y:2016 05 2016 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,032 $900 Implemented
UA0163 # 04 Y:2016 04 2016 USE RADIANT HEATER FOR SPOT HEATING $8,072 $23,240 Not Implemented
UA0163 # 03 Y:2016 03 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $54,002 $184,407 Not Implemented