Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,264
matching recommendationsNAICS | 3391 | Medical Equipment and Supplies Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0811 # 05 Y:2020 | 05 | 2020 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,738 | $14,935 | Not Implemented |
MA0811 # 06 Y:2020 | 06 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,545 | $1,000 | Not Implemented |
MA0811 # 07 Y:2020 | 07 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $380 | $1,000 | Not Implemented |
MA0811 # 08 Y:2020 | 08 | 2020 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $676 | $500 | Not Implemented |
NL0040 # 01 Y:2019 | 01 | 2019 | OPTIMIZE PLANT POWER FACTOR | $106,822 | $130,000 | Not Implemented |
NL0040 # 02 Y:2019 | 02 | 2019 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $38,925 | $150,000 | Not Implemented |
NL0040 # 03 Y:2019 | 03 | 2019 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $25,402 | $1,697 | Implemented |
NL0040 # 04 Y:2019 | 04 | 2019 | REPAIR OR REPLACE STEAM TRAPS | $16,450 | $4,500 | Implemented |
NL0040 # 05 Y:2019 | 05 | 2019 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $10,400 | $51,350 | Implemented |
NL0040 # 06 Y:2019 | 06 | 2019 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $9,900 | $3,660 | Not Implemented |
NL0040 # 07 Y:2019 | 07 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,049 | $18,439 | Implemented |
NL0040 # 08 Y:2019 | 08 | 2019 | RECYCLE WHITE WATER | $2,649 | $1,000 | Implemented |
WV0587 # 01 Y:2019 | 01 | 2019 | UPGRADE CONTROLS ON COMPRESSORS | $77,971 | $40,873 | Not Implemented |
WV0587 # 02 Y:2019 | 02 | 2019 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $67,428 | $29,350 | Not Implemented |
WV0587 # 03 Y:2019 | 03 | 2019 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $32,679 | $11,750 | Not Implemented |
WV0587 # 04 Y:2019 | 04 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,887 | $4,500 | Implemented |
WV0587 # 05 Y:2019 | 05 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,112 | $300 | Implemented |
WV0587 # 06 Y:2019 | 06 | 2019 | MINIMIZE WATER USAGE | $7,337 | $6,300 | Not Implemented |
WV0587 # 07 Y:2019 | 07 | 2019 | DEVELOP A REPAIR/REPLACE POLICY | $5,261 | $650 | Implemented |
WV0587 # 08 Y:2019 | 08 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,563 | $600 | Implemented |
WV0587 # 09 Y:2019 | 09 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,481 | $0 | Not Implemented |
WV0587 # 10 Y:2019 | 10 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,319 | $8,500 | Not Implemented |
WV0587 # 11 Y:2019 | 11 | 2019 | INSULATE BARE EQUIPMENT | $2,257 | $2,624 | Implemented |
WV0587 # 12 Y:2019 | 12 | 2019 | INSTALL OCCUPANCY SENSORS | $1,787 | $1,750 | Implemented |
WV0587 # 13 Y:2019 | 13 | 2019 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,138 | $6,500 | Not Implemented |