Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

78

matching recommendations
Reset
NAICS 339114 Dental Equipment and Supplies Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UK1310 # 02 Y:2013 02 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,611 $11,808 Not Implemented
UK1310 # 01 Y:2013 01 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,458 $1,500 Implemented
UK1310 # 04 Y:2013 04 2013 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $348 $60 Implemented
UK1310 # 05 Y:2013 05 2013 MINIMIZE WATER USAGE $5,952 $14,400 Not Implemented
DL0075 # 02 Y:2011 02 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $32,000 $10,910 Not Implemented
DL0075 # 01 Y:2011 01 2011 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $17,900 $6,660 Not Implemented
DL0075 # 03 Y:2011 03 2011 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $14,910 $47,500 Not Implemented
DL0075 # 04 Y:2011 04 2011 PREHEAT COMBUSTION AIR WITH WASTE HEAT $6,900 $2,920 Not Implemented
DL0075 # 05 Y:2011 05 2011 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $6,900 $9,250 Not Implemented
DL0075 # 06 Y:2011 06 2011 RECOVER WASTE HEAT FROM EQUIPMENT $4,000 $5,000 Not Implemented
DL0075 # 07 Y:2011 07 2011 RECOVER WASTE HEAT FROM EQUIPMENT $3,281 $5,000 Not Implemented
DL0075 # 08 Y:2011 08 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $719 $1,100 Not Implemented
DL0075 # 09 Y:2011 09 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,400 $740 Not Implemented
NC0373 # 05 Y:2008 05 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,639 $5,398 Implemented
NC0373 # 01 Y:2008 01 2008 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $4,343 $15,000 Not Implemented
NC0373 # 02 Y:2008 02 2008 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $13,018 $26,250 Not Implemented
NC0373 # 03 Y:2008 03 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $650 $100 Implemented
NC0373 # 04 Y:2008 04 2008 RECOVER WASTE HEAT FROM EQUIPMENT $4,993 $16,000 Not Implemented
NC0373 # 06 Y:2008 06 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,879 $9,158 Implemented
GT0812 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,096 $24,867 Implemented
GT0812 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $195 $221 Implemented
GT0812 # 04 Y:2005 04 2005 UTILIZE A LESS EXPENSIVE COOLING METHOD $283 $300 Not Implemented
GT0812 # 03 Y:2005 03 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $469 $400 Not Implemented
GT0812 # 02 Y:2005 02 2005 INSTALL TIMERS AND/OR THERMOSTATS $20,280 $10,000 Implemented
GT0812 # 01 Y:2005 01 2005 USE SYNTHETIC LUBRICANT $600 $0 Implemented