Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,372

matching recommendations
Reset
NAICS 3399 Other Miscellaneous Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0481 # 09 Y:2019 09 2019 RECOVER WASTE HEAT FROM EQUIPMENT $390 $1,850 Implemented
WV0583 # 01 Y:2019 01 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $26,290 $53,184 Implemented
WV0583 # 02 Y:2019 02 2019 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,666 $2,560 Not Implemented
WV0583 # 03 Y:2019 03 2019 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $6,740 $4,320 Not Implemented
WV0583 # 04 Y:2019 04 2019 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,446 $28 Implemented
WV0583 # 05 Y:2019 05 2019 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,448 $0 Implemented
WV0583 # 06 Y:2019 06 2019 UPGRADE CONTROLS ON COMPRESSORS $2,254 $5,905 Not Implemented
WV0583 # 07 Y:2019 07 2019 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,271 $607 Implemented
WV0583 # 08 Y:2019 08 2019 DEVELOP A REPAIR/REPLACE POLICY $1,265 $582 Implemented
WV0583 # 09 Y:2019 09 2019 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $507 $270 Implemented
UA0214 # 01 Y:2019 01 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,674 $35,762 Implemented
UA0214 # 02 Y:2019 02 2019 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,341 $8,495 Implemented
UA0214 # 03 Y:2019 03 2019 TURN OFF EQUIPMENT WHEN NOT IN USE $22,118 $50 Implemented
UA0214 # 04 Y:2019 04 2019 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $48,099 $7,241 Implemented
UA0214 # 05 Y:2019 05 2019 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,824 $6,704 Implemented
UA0214 # 06 Y:2019 06 2019 TURN OFF EQUIPMENT WHEN NOT IN USE $58,766 $50 Not Implemented
UA0214 # 07 Y:2019 07 2019 TURN OFF EQUIPMENT WHEN NOT IN USE $57,024 $7,375 Implemented
UA0214 # 08 Y:2019 08 2019 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $33,548 $5,698 Not Implemented
UA0214 # 09 Y:2019 09 2019 PAY UTILITY BILLS ON TIME $9,417 $0 Implemented
WM0137 # 01 Y:2019 01 2019 USE SOLAR HEAT TO MAKE ELECTRICTY $19,250 $106,000 Not Implemented
WM0137 # 02 Y:2019 02 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,626 $15,385 Implemented
WM0137 # 03 Y:2019 03 2019 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,072 $3,048 Not Implemented
WM0137 # 04 Y:2019 04 2019 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $4,181 $0 Not Implemented
WM0137 # 05 Y:2019 05 2019 USE RADIANT HEATER FOR SPOT HEATING $2,291 $2,780 Implemented
WM0137 # 06 Y:2019 06 2019 INSTALL OCCUPANCY SENSORS $2,143 $2,415 Not Implemented