Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
61
matching recommendationsNAICS | 451110 | Sporting Goods Stores |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CI0004 # 06 Y:2022 | 06 | 2022 | INSTALL OCCUPANCY SENSORS | $1,464 | $2,000 | Not Implemented |
CI0004 # 05 Y:2022 | 05 | 2022 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $4,787 | $8,000 | Not Implemented |
CI0004 # 04 Y:2022 | 04 | 2022 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,843 | $8,200 | Not Implemented |
CI0004 # 03 Y:2022 | 03 | 2022 | USE PHOTOCELL CONTROLS | $8,537 | $4,050 | Not Implemented |
CI0004 # 01 Y:2022 | 01 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $34,971 | $218,747 | Not Implemented |
CI0004 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,110 | $75,225 | Not Implemented |
CM1003 # 06 Y:2022 | 06 | 2022 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,296 | $38,900 | Not Implemented |
CM1003 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $66,142 | $89,970 | Not Implemented |
CM1003 # 03 Y:2022 | 03 | 2022 | USE PHOTOCELL CONTROLS | $780 | $370 | Not Implemented |
CM1003 # 04 Y:2022 | 04 | 2022 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $227 | $0 | Not Implemented |
CM1003 # 05 Y:2022 | 05 | 2022 | INSTALL SUB-METERING EQUIPMENT | $21,570 | $3,250 | Not Implemented |
CM1003 # 02 Y:2022 | 02 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $11,084 | $182,500 | Not Implemented |
ORC002 # 03 Y:2022 | 03 | 2022 | REDUCE VENTILATION AIR | $4,722 | $300 | Not Implemented |
ORC002 # 02 Y:2022 | 02 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $390 | $300 | Not Implemented |
ORC002 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,504 | $26,686 | Not Implemented |
ORC002 # 04 Y:2022 | 04 | 2022 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,705 | $8,500 | Not Implemented |
MS0400 # 01 Y:2022 | 01 | 2022 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,137 | $0 | Not Implemented |
MS0400 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $421 | $2,011 | Not Implemented |
MS0400 # 03 Y:2022 | 03 | 2022 | REDUCE HEAT GAIN BY WINDOW TINTING | $4,268 | $39,618 | Not Implemented |
MS0400 # 04 Y:2022 | 04 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $37 | $0 | Not Implemented |
MS0400 # 05 Y:2022 | 05 | 2022 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $53 | $398 | Not Implemented |
ORC001 # 04 Y:2022 | 04 | 2022 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,439 | $6,750 | Implemented |
ORC001 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,145 | $29,612 | Implemented |
ORC001 # 02 Y:2022 | 02 | 2022 | INSTALL OCCUPANCY SENSORS | $455 | $1,200 | Implemented |
ORC001 # 03 Y:2022 | 03 | 2022 | REDUCE VENTILATION AIR | $3,194 | $300 | Implemented |