Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
201
matching recommendationsNAICS | 4931 | Warehousing and Storage |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0602 # 04 Y:2025 | 04 | 2025 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,370 | $190 | n/a |
AS0602 # 05 Y:2025 | 05 | 2025 | INSTALL TIMERS AND/OR THERMOSTATS | $344 | $1,177 | n/a |
AS0602 # 01 Y:2025 | 01 | 2025 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $6,811 | $689 | n/a |
UD1106 # 03 Y:2025 | 03 | 2025 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,902 | $8,000 | n/a |
UD1106 # 01 Y:2025 | 01 | 2025 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $14,990 | $0 | n/a |
UD1106 # 02 Y:2025 | 02 | 2025 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $411 | $1,920 | n/a |
AS0593 # 01 Y:2024 | 01 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $49,329 | $404,249 | n/a |
AS0593 # 07 Y:2024 | 07 | 2024 | SHADE WINDOWS FROM SUMMER SUN | $1,446 | $7,920 | n/a |
AS0593 # 06 Y:2024 | 06 | 2024 | UPGRADE CONTROLS ON COMPRESSORS | $1,850 | $4,090 | n/a |
AS0593 # 04 Y:2024 | 04 | 2024 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,253 | $50,000 | n/a |
AS0593 # 05 Y:2024 | 05 | 2024 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $6,940 | $2,800 | n/a |
AS0593 # 03 Y:2024 | 03 | 2024 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $11,079 | $1,005 | n/a |
AS0593 # 02 Y:2024 | 02 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,424 | $10,321 | n/a |
AS0593 # 08 Y:2024 | 08 | 2024 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,045 | $715 | n/a |
AS0593 # 09 Y:2024 | 09 | 2024 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $481 | $120 | n/a |
AS0593 # 10 Y:2024 | 10 | 2024 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $370 | $90 | n/a |
AS0593 # 11 Y:2024 | 11 | 2024 | INSTALL OCCUPANCY SENSORS | $189 | $180 | n/a |
LS0225 # 04 Y:2025 | 04 | 2025 | USE SOLAR HEAT TO MAKE ELECTRICTY | $38,911 | $514,800 | n/a |
LS0225 # 03 Y:2025 | 03 | 2025 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $3,877 | $29,510 | n/a |
LS0225 # 02 Y:2025 | 02 | 2025 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,607 | $2,927 | n/a |
LS0225 # 01 Y:2025 | 01 | 2025 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $4,695 | $0 | n/a |
UD1095 # 01 Y:2024 | 01 | 2024 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $252 | $1,500 | n/a |
UD1095 # 03 Y:2024 | 03 | 2024 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $13,050 | $0 | n/a |
UD1095 # 02 Y:2024 | 02 | 2024 | ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION | $581 | $10,500 | n/a |
AS0578 # 03 Y:2024 | 03 | 2024 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $569 | $810 | Not Implemented |