Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
173
matching recommendationsNAICS | 541 | Professional, Scientific, and Technical Services |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0205 # 01 Y:2022 | 01 | 2022 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $820 | $0 | Not Implemented |
DL0205 # 02 Y:2022 | 02 | 2022 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $3,896 | $0 | Not Implemented |
DL0205 # 04 Y:2022 | 04 | 2022 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $15,368 | $0 | Implemented |
DL0205 # 09 Y:2022 | 09 | 2022 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $21,960 | $20,995 | Not Implemented |
DL0205 # 08 Y:2022 | 08 | 2022 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,193 | $3,716 | Not Implemented |
DL0205 # 07 Y:2022 | 07 | 2022 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,276 | $64 | Not Implemented |
DL0205 # 06 Y:2022 | 06 | 2022 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,057 | $0 | Not Implemented |
DL0205 # 03 Y:2022 | 03 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,040 | $0 | Not Implemented |
DL0204 # 06 Y:2022 | 06 | 2022 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $8,754 | $18,145 | Not Implemented |
DL0204 # 07 Y:2022 | 07 | 2022 | ADJUST VENTS TO MINIMIZE ENERGY USE | $836 | $465 | Implemented |
DL0204 # 08 Y:2022 | 08 | 2022 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $6,857 | $0 | Not Implemented |
DL0204 # 05 Y:2022 | 05 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,599 | $24,771 | Not Implemented |
DL0204 # 04 Y:2022 | 04 | 2022 | DEVELOP A REPAIR/REPLACE POLICY | $32,583 | $1,300 | Not Implemented |
DL0204 # 03 Y:2022 | 03 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $491 | $45 | Implemented |
DL0204 # 02 Y:2022 | 02 | 2022 | USE OPTIMUM TEMPERATURE | $1,182 | $0 | Implemented |
DL0204 # 01 Y:2022 | 01 | 2022 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $18,234 | $0 | Not Implemented |
MS0395 # 03 Y:2022 | 03 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $677 | $540 | Implemented |
MS0395 # 04 Y:2022 | 04 | 2022 | UPGRADE OBSOLETE EQUIPMENT | $2,447 | $15,480 | Not Implemented |
MS0395 # 01 Y:2022 | 01 | 2022 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,342 | $210,000 | Not Implemented |
MS0395 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,723 | $18,748 | Implemented |
DL0202 # 03 Y:2021 | 03 | 2021 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,460 | $1,000 | Implemented |
DL0202 # 06 Y:2021 | 06 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $870 | $0 | Implemented |
DL0202 # 04 Y:2021 | 04 | 2021 | BURN WASTE OIL FOR HEAT | $12,350 | $5,000 | Implemented |
DL0202 # 05 Y:2021 | 05 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $37,058 | $24,746 | Not Implemented |
DL0202 # 08 Y:2021 | 08 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $20,900 | $50,000 | Not Implemented |