Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
334
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0287 # 08 Y:1997 | 08 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $320 | $270 | Not Implemented |
ND0287 # 09 Y:1997 | 09 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $269 | $1,000 | Not Implemented |
ND0287 # 10 Y:1997 | 10 | 1997 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $170 | $0 | Not Implemented |
ND0287 # 11 Y:1997 | 11 | 1997 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $89 | $300 | Not Implemented |
ND0233 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,844 | $9,060 | Implemented |
ND0233 # 02 Y:1995 | 02 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,460 | $5,000 | Not Implemented |
ND0233 # 03 Y:1995 | 03 | 1995 | OPTIMIZE PLANT POWER FACTOR | $10,896 | $16,110 | Not Implemented |
ND0233 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,924 | $319 | Implemented |
ND0224 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $14,560 | $38,000 | Implemented |
ND0224 # 02 Y:1995 | 02 | 1995 | INSTALL OCCUPANCY SENSORS | $3,594 | $2,000 | Not Implemented |
ND0224 # 03 Y:1995 | 03 | 1995 | OPTIMIZE PLANT POWER FACTOR | $1,900 | $3,105 | Not Implemented |
ND0224 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,300 | $240 | Implemented |
ND0224 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $807 | $478 | Not Implemented |
ND0224 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $215 | $1,090 | Implemented |
ND0216 # 01 Y:1995 | 01 | 1995 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $14,019 | $250 | Implemented |
ND0216 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,139 | $6,905 | Not Implemented |
ND0216 # 03 Y:1995 | 03 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $118 | $120 | Implemented |
ND0216 # 04 Y:1995 | 04 | 1995 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,634 | $250 | Implemented |
ND0216 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $848 | $590 | Not Implemented |
ND0216 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $458 | $950 | Not Implemented |
ND0216 # 07 Y:1995 | 07 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $242 | $390 | Not Implemented |
ND0216 # 08 Y:1995 | 08 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $154 | $760 | Not Implemented |
ND0216 # 09 Y:1995 | 09 | 1995 | RECOVER AND REUSE WASTE MATERIAL | $1,920 | $0 | Not Implemented |
ND0200 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $11,000 | $11,920 | Not Implemented |
ND0200 # 02 Y:1994 | 02 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,112 | $1,500 | Not Implemented |