Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

709

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NV0026 # 05 Y:1995 05 1995 INSULATE BARE EQUIPMENT $1,356 $60 Not Implemented
NV0026 # 06 Y:1995 06 1995 INSULATE BARE EQUIPMENT $512 $320 Implemented
NV0026 # 07 Y:1995 07 1995 REPAIR AND ELIMINATE STEAM LEAKS $468 $20 Not Implemented
WI0232 # 01 Y:1995 01 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,507 $500 Not Implemented
WI0232 # 02 Y:1995 02 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,343 $10,000 Not Implemented
WI0232 # 03 Y:1995 03 1995 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,427 $20 Not Implemented
WI0232 # 04 Y:1995 04 1995 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,004 $0 Not Implemented
WI0232 # 05 Y:1995 05 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,246 $1,805 Not Implemented
WI0232 # 06 Y:1995 06 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $188 $0 Not Implemented
WI0232 # 07 Y:1995 07 1995 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $401 $260 Not Implemented
WI0232 # 08 Y:1995 08 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $244 $640 Not Implemented
WI0232 # 09 Y:1995 09 1995 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $139 $0 Not Implemented
AS0141 # 01 Y:1995 01 1995 RECOVER WASTE HEAT FROM EQUIPMENT $1,522 $4,250 Not Implemented
AS0141 # 02 Y:1995 02 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $991 $849 Not Implemented
AS0141 # 03 Y:1995 03 1995 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $4,234 $9,000 Not Implemented
AS0141 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,099 $7,115 Not Implemented
AS0141 # 05 Y:1995 05 1995 INSTALL OCCUPANCY SENSORS $921 $975 Not Implemented
AS0141 # 06 Y:1995 06 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $557 $0 Not Implemented
AS0141 # 07 Y:1995 07 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $204 $240 Not Implemented
OD0026 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,710 $3,687 Implemented
OD0026 # 02 Y:1995 02 1995 INSULATE BARE EQUIPMENT $1,012 $400 Implemented
OD0026 # 03 Y:1995 03 1995 INSULATE BARE EQUIPMENT $224 $94 Not Implemented
OD0026 # 04 Y:1995 04 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $37 $54 Implemented
SF0054 # 01 Y:1995 01 1995 INSULATE BARE EQUIPMENT $2,173 $1,215 Implemented
SF0054 # 02 Y:1995 02 1995 REPAIR AND ELIMINATE STEAM LEAKS $2,344 $525 Implemented