Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

975

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0064 # 04 Y:1986 04 1986 IMPROVE LUBRICATION PRACTICES $734 $0 Not Implemented
CO0064 # 05 Y:1986 05 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $669 $1,200 Not Implemented
CO0064 # 06 Y:1986 06 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $983 $100 Implemented
CO0064 # 07 Y:1986 07 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,032 $1,260 Not Implemented
CO0065 # 01 Y:1986 01 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,628 $300 Implemented
CO0065 # 02 Y:1986 02 1986 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,367 $800 Not Implemented
CO0065 # 03 Y:1986 03 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $997 $300 Not Implemented
CO0065 # 04 Y:1986 04 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $912 $1,200 Implemented
CO0065 # 05 Y:1986 05 1986 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $2,772 $7,500 Not Implemented
CO0065 # 06 Y:1986 06 1986 USE DEMAND CONTROLLER OR LOAD SHEDDER $5,124 $3,600 Not Implemented
CO0065 # 07 Y:1986 07 1986 USE RADIANT HEATER FOR SPOT HEATING $6,995 $6,000 Not Implemented
CO0065 # 08 Y:1986 08 1986 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $3,715 $3,750 Implemented
CO0065 # 09 Y:1986 09 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $697 $300 Implemented
CO0065 # 10 Y:1986 10 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $522 $760 Not Implemented
CO0065 # 11 Y:1986 11 1986 INSTALL TIMERS AND/OR THERMOSTATS $521 $85 Implemented
CO0065 # 12 Y:1986 12 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,951 $1,328 Implemented
CO0061 # 01 Y:1986 01 1986 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,180 $675 Implemented
CO0061 # 02 Y:1986 02 1986 INSTALL TIMERS AND/OR THERMOSTATS $2,701 $4,000 Implemented
CO0061 # 03 Y:1986 03 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $673 $3,000 Implemented
CO0061 # 04 Y:1986 04 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,929 $1,500 Not Implemented
CO0061 # 05 Y:1986 05 1986 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $2,472 $800 Not Implemented
CO0061 # 06 Y:1986 06 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $129 $300 Not Implemented
CO0061 # 07 Y:1986 07 1986 INSTALL TURBULATORS $557 $1,000 Not Implemented
CO0061 # 08 Y:1986 08 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $556 $900 Not Implemented
CO0061 # 09 Y:1986 09 1986 IMPROVE LUBRICATION PRACTICES $689 $0 Implemented