Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

284

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OD0163 # 03 Y:2000 03 2000 INSTALL OCCUPANCY SENSORS $50 $95 Not Implemented
OD0163 # 04 Y:2000 04 2000 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $104 $285 Not Implemented
OD0155 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,185 $26,708 Implemented
OD0155 # 02 Y:2000 02 2000 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $1,414 $1,200 Not Implemented
OD0155 # 03 Y:2000 03 2000 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $450 $179 Implemented
OD0156 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,988 $7,743 Implemented
OD0156 # 02 Y:2000 02 2000 TURN OFF EQUIPMENT WHEN NOT IN USE $6,143 $0 Not Implemented
OD0156 # 03 Y:2000 03 2000 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $148 $209 Implemented
OD0156 # 04 Y:2000 04 2000 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $581 $0 Not Implemented
OD0156 # 05 Y:2000 05 2000 MINIMIZE WATER USAGE $26,775 $6,000 Not Implemented
OD0150 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,354 $9,564 Not Implemented
OD0150 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $370 $400 Not Implemented
OD0150 # 03 Y:1999 03 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $402 $20 Not Implemented
OD0150 # 04 Y:1999 04 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $611 $3,660 Not Implemented
OD0150 # 05 Y:1999 05 1999 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $779 $0 Not Implemented
OD0152 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,265 $10,172 Not Implemented
OD0152 # 02 Y:2000 02 2000 INSTALL OCCUPANCY SENSORS $911 $950 Not Implemented
OD0152 # 03 Y:2000 03 2000 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,598 $0 Not Implemented
OD0152 # 04 Y:2000 04 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $749 $360 Not Implemented
OD0152 # 05 Y:2000 05 2000 USE SYNTHETIC LUBRICANT $478 $156 Not Implemented
OD0152 # 06 Y:2000 06 2000 REPAIR OR REPLACE STEAM TRAPS $3,005 $225 Not Implemented
OD0152 # 07 Y:2000 07 2000 REPAIR AND ELIMINATE STEAM LEAKS $2,357 $680 Not Implemented
OD0152 # 08 Y:2000 08 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $452 $1,000 Not Implemented
OD0146 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $279 $1,390 Not Implemented
OD0146 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $185 $90 Implemented