IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,785

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0082 # 02 Y:1990 02 1990 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $4,429 $0 Implemented
WI0082 # 03 Y:1990 03 1990 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,347 $3,300 Not Implemented
WI0082 # 04 Y:1990 04 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,973 $5,000 Not Implemented
WI0082 # 05 Y:1990 05 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $801 $848 Implemented
WI0082 # 06 Y:1990 06 1990 INSTALL TIMERS AND/OR THERMOSTATS $1,333 $750 Implemented
WI0082 # 07 Y:1990 07 1990 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $235 $0 Implemented
WI0082 # 08 Y:1990 08 1990 INSTALL SET-BACK TIMERS $143 $200 Not Implemented
WI0082 # 09 Y:1990 09 1990 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $137 $0 Implemented
WI0082 # 10 Y:1990 10 1990 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $60 $200 Not Implemented
TN0394 # 01 Y:1990 01 1990 HEAT WATER WITH EXHAUST HEAT $54,274 $73,320 Not Implemented
TN0394 # 02 Y:1990 02 1990 INSTALL / REPAIR INSULATION ON STEAM LINES $5,454 $2,060 Implemented
TN0394 # 03 Y:1990 03 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,219 $1,000 Not Implemented
TN0394 # 04 Y:1990 04 1990 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,298 $0 Implemented
TN0394 # 05 Y:1990 05 1990 INSULATE BARE EQUIPMENT $513 $565 Not Implemented
TN0394 # 06 Y:1990 06 1990 INSTALL TIMERS AND/OR THERMOSTATS $1,838 $840 Implemented
TN0394 # 07 Y:1990 07 1990 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $668 $1,963 Implemented
TN0394 # 08 Y:1990 08 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $451 $270 Implemented
TN0394 # 09 Y:1990 09 1990 INSULATE BARE EQUIPMENT $167 $459 Implemented
AS0002 # 01 Y:1990 01 1990 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT $281,965 $1,050,000 Not Implemented
AS0002 # 02 Y:1990 02 1990 OPERATE BOILERS ON HIGH FIRE SETTING $18,029 $100,000 Implemented
AS0002 # 03 Y:1990 03 1990 INSTALL SET-BACK TIMERS $7,055 $3,521 Implemented
AS0002 # 04 Y:1990 04 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,653 $1,000 Implemented
AS0002 # 05 Y:1990 05 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,704 $2,813 Implemented
AS0002 # 06 Y:1990 06 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $262 $335 Not Implemented
AS0002 # 07 Y:1990 07 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $343 $427 Implemented