Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,939

matching recommendations
Reset
SIC 201 Meat Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0513 # 03 Y:2006 03 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $58,300 $37,200 Implemented
AM0513 # 04 Y:2006 04 2006 REPAIR AND ELIMINATE STEAM LEAKS $49,600 $5,000 Implemented
AM0513 # 05 Y:2006 05 2006 INSULATE BARE EQUIPMENT $8,120 $300 Implemented
AM0513 # 06 Y:2006 06 2006 USE SYNTHETIC LUBRICANT $3,390 $0 Not Implemented
AM0513 # 07 Y:2006 07 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,780 $290 Not Implemented
AM0513 # 08 Y:2006 08 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,450 $0 Implemented
AM0513 # 09 Y:2006 09 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,170 $144 Implemented
AM0513 # 10 Y:2006 10 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,415 $690 Implemented
IC0115 # 01 Y:2006 01 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,445 $26,134 Implemented
IC0115 # 02 Y:2006 02 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,985 $16,831 Implemented
IC0115 # 03 Y:2006 03 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,680 $65,036 Implemented
IC0115 # 04 Y:2006 04 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $272 $420 Implemented
IC0115 # 05 Y:2006 05 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $159 $380 Not Implemented
IC0115 # 06 Y:2006 06 2006 INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM $54 $284 Implemented
IC0115 # 07 Y:2006 07 2006 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $142,200 $195,625 Not Implemented
IC0115 # 08 Y:2006 08 2006 REPLACE BOILER $125,042 $193,200 Implemented
IC0115 # 09 Y:2006 09 2006 REDUCE EXCESS STEAM BLEEDING $29,262 $5,000 Implemented
MS0293 # 01 Y:2006 01 2006 INSULATE BARE EQUIPMENT $3,933 $670 Not Implemented
MS0293 # 02 Y:2006 02 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,385 $176 Not Implemented
MS0293 # 03 Y:2006 03 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,307 $2,895 Not Implemented
MS0293 # 04 Y:2006 04 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,168 $7,343 Not Implemented
MS0293 # 05 Y:2006 05 2006 BURN WASTE OIL FOR HEAT $564 $3,595 Not Implemented
MS0293 # 06 Y:2006 06 2006 INSULATE BARE EQUIPMENT $421 $55 Not Implemented
MS0293 # 07 Y:2006 07 2006 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $351 $210 Not Implemented
MS0293 # 08 Y:2006 08 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $235 $62 Not Implemented