Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
245
matching recommendationsSIC | 201 | Meat Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0374 # 05 Y:1989 | 05 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $22 | $200 | Not Implemented |
GT0377 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,468 | $2,940 | Implemented |
GT0377 # 02 Y:1989 | 02 | 1989 | INCREASE AMOUNT OF CONDENSATE RETURNED | $12,750 | $27,000 | Implemented |
GT0377 # 03 Y:1989 | 03 | 1989 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $3,740 | $15,000 | Not Implemented |
GT0377 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,330 | $7,990 | Not Implemented |
GT0377 # 05 Y:1989 | 05 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,623 | $2,035 | Implemented |
GT0377 # 06 Y:1989 | 06 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $528 | $0 | Implemented |
GT0332 # 01 Y:1987 | 01 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $771 | $1,786 | Implemented |
GT0332 # 02 Y:1987 | 02 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $226 | $580 | Implemented |
GT0332 # 03 Y:1987 | 03 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,200 | $300 | Implemented |
GT0332 # 04 Y:1987 | 04 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,070 | $12,000 | Implemented |
GT0332 # 05 Y:1987 | 05 | 1987 | HEAT WATER WITH EXHAUST HEAT | $16,300 | $5,800 | Implemented |
GT0332 # 06 Y:1987 | 06 | 1987 | COVER OPEN TANKS | $1,130 | $2,000 | Implemented |
GT0299 # 01 Y:1986 | 01 | 1986 | INSULATE BARE EQUIPMENT | $818 | $2,688 | Implemented |
GT0299 # 02 Y:1986 | 02 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,563 | $0 | Implemented |
GT0299 # 03 Y:1986 | 03 | 1986 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $20,878 | $34,000 | Implemented |
GT0299 # 04 Y:1986 | 04 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $574 | $983 | Not Implemented |
GT0299 # 05 Y:1986 | 05 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,032 | $4,245 | Implemented |
GT0299 # 06 Y:1986 | 06 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $488 | $219 | Not Implemented |
GT0299 # 07 Y:1986 | 07 | 1986 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,163 | $3,000 | Implemented |
GT0282 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $677 | $133 | Implemented |
GT0282 # 02 Y:1986 | 02 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $152 | $90 | Implemented |
GT0282 # 03 Y:1986 | 03 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $498 | $300 | Implemented |
GT0282 # 04 Y:1986 | 04 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $940 | $187 | Implemented |
GT0282 # 05 Y:1986 | 05 | 1986 | HEAT WATER WITH EXHAUST HEAT | $4,519 | $16,000 | Not Implemented |