IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,731

matching recommendations
Reset
SIC 202 Dairy Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0030 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,698 $2,199 Not Implemented
BD0030 # 07 Y:1995 07 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,508 $1,020 Not Implemented
DS0027 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,015 $1,423 Implemented
DS0027 # 02 Y:1995 02 1995 INSTALL OCCUPANCY SENSORS $2,292 $5,958 Not Implemented
DS0027 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,509 $7,430 Not Implemented
DS0027 # 04 Y:1995 04 1995 OPTIMIZE PLANT POWER FACTOR $4,989 $16,420 Not Implemented
DS0027 # 05 Y:1995 05 1995 INSULATE BARE EQUIPMENT $905 $177 Not Implemented
DS0027 # 06 Y:1995 06 1995 INSULATE BARE EQUIPMENT $595 $77 Not Implemented
DS0027 # 07 Y:1995 07 1995 INSULATE BARE EQUIPMENT $158 $87 Not Implemented
DS0027 # 08 Y:1995 08 1995 RECOVER WASTE HEAT FROM EQUIPMENT $10,397 $15,000 Not Implemented
DS0027 # 09 Y:1995 09 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $2,990 $0 Not Implemented
DS0027 # 10 Y:1995 10 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $798 $599 Not Implemented
KG0019 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,677 $15,450 Implemented
KG0019 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,148 $453 Implemented
KG0019 # 03 Y:1995 03 1995 INSULATE BARE EQUIPMENT $1,300 $107 Implemented
KG0019 # 04 Y:1995 04 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,079 $1,470 Not Implemented
KG0019 # 05 Y:1995 05 1995 INSTALL OCCUPANCY SENSORS $795 $260 Implemented
KG0019 # 06 Y:1995 06 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $421 $1,250 Implemented
KG0019 # 07 Y:1995 07 1995 INSTALL TIMERS AND/OR THERMOSTATS $419 $300 Not Implemented
WI0232 # 01 Y:1995 01 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,507 $500 Not Implemented
WI0232 # 02 Y:1995 02 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,343 $10,000 Not Implemented
WI0232 # 03 Y:1995 03 1995 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,427 $20 Not Implemented
WI0232 # 04 Y:1995 04 1995 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,004 $0 Not Implemented
WI0232 # 05 Y:1995 05 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,246 $1,805 Not Implemented
WI0232 # 06 Y:1995 06 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $188 $0 Not Implemented