Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,773

matching recommendations
Reset
SIC 202 Dairy Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DS0003 # 10 Y:1994 10 1994 INSULATE BARE EQUIPMENT $1,612 $1,248 Not Implemented
DS0003 # 11 Y:1994 11 1994 INSULATE BARE EQUIPMENT $201 $153 Not Implemented
DS0003 # 12 Y:1994 12 1994 INSULATE BARE EQUIPMENT $150 $138 Not Implemented
DS0003 # 13 Y:1994 13 1994 INCREASE AMOUNT OF CONDENSATE RETURNED $22,360 $4,000 Not Implemented
AM0212 # 01 Y:1994 01 1994 INCREASE AMOUNT OF CONDENSATE RETURNED $920 $3,180 Not Implemented
AM0212 # 02 Y:1994 02 1994 INCREASE AMOUNT OF CONDENSATE RETURNED $550 $470 Not Implemented
AM0212 # 03 Y:1994 03 1994 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $140 $0 Implemented
AM0212 # 04 Y:1994 04 1994 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $190 $580 Not Implemented
OR0204 # 01 Y:1994 01 1994 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $11,122 $5,000 Implemented
OR0204 # 02 Y:1994 02 1994 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $912 $3,000 Implemented
OR0204 # 03 Y:1994 03 1994 RECOVER WASTE HEAT FROM EQUIPMENT $7,860 $8,997 Implemented
OR0204 # 04 Y:1994 04 1994 OPTIMIZE PLANT POWER FACTOR $4,057 $5,100 Not Implemented
OR0204 # 05 Y:1994 05 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $2,378 $1,394 Implemented
OR0204 # 06 Y:1994 06 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $376 $1,075 Implemented
AR0017 # 01 Y:1994 01 1994 INSULATE BARE EQUIPMENT $34,041 $3,140 Implemented
AR0017 # 02 Y:1994 02 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,002 $988 Implemented
AR0017 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,208 $9,070 Implemented
AR0017 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,786 $100 Implemented
AR0017 # 05 Y:1994 05 1994 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $113,613 $70,000 Not Implemented
AR0017 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,302 $802 Implemented
AS0112 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,087 $15,256 Implemented
AS0112 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,310 $37,932 Implemented
AS0112 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,174 $9,280 Not Implemented
AS0112 # 04 Y:1994 04 1994 INSTALL OCCUPANCY SENSORS $1,508 $525 Not Implemented
AS0112 # 05 Y:1994 05 1994 USE PHOTOCELL CONTROLS $1,035 $400 Implemented