Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsSIC | 202 | Dairy Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0188 # 01 Y:1993 | 01 | 1993 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,784 | $15,000 | Implemented |
OR0188 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,389 | $1,320 | Implemented |
OR0188 # 03 Y:1993 | 03 | 1993 | OPTIMIZE PLANT POWER FACTOR | $1,031 | $750 | Not Implemented |
OR0188 # 04 Y:1993 | 04 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $17 | $84 | Implemented |
KU0407 # 07 Y:1993 | 07 | 1993 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,611 | $0 | Not Implemented |
KU0407 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $444 | $563 | Implemented |
KU0407 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,620 | $1,120 | Implemented |
KU0407 # 04 Y:1993 | 04 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,730 | $200 | Implemented |
KU0407 # 03 Y:1993 | 03 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $986 | $2,400 | Not Implemented |
KU0407 # 02 Y:1993 | 02 | 1993 | INSULATE BARE EQUIPMENT | $3,653 | $9,978 | Not Implemented |
KU0407 # 01 Y:1993 | 01 | 1993 | UPGRADE OBSOLETE EQUIPMENT | $15,428 | $3,583 | Implemented |
IA0061 # 06 Y:1993 | 06 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $220 | $353 | Not Implemented |
IA0061 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $110 | $120 | Implemented |
IA0061 # 05 Y:1993 | 05 | 1993 | INSULATE BARE EQUIPMENT | $3,751 | $3,660 | Not Implemented |
IA0061 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,928 | $1,939 | Implemented |
IA0061 # 03 Y:1993 | 03 | 1993 | REPLACE BOILER | $15,800 | $23,150 | Not Implemented |
IA0061 # 02 Y:1993 | 02 | 1993 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $68,521 | $75,677 | Not Implemented |
IA0061 # 01 Y:1993 | 01 | 1993 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $136,096 | $379,828 | Not Implemented |
IA0058 # 01 Y:1993 | 01 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,306 | $1,000 | Implemented |
IA0058 # 08 Y:1993 | 08 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $537 | $1,100 | Not Implemented |
IA0058 # 07 Y:1993 | 07 | 1993 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $7,910 | $30,000 | Not Implemented |
IA0058 # 06 Y:1993 | 06 | 1993 | INSTALL OCCUPANCY SENSORS | $4,847 | $1,899 | Not Implemented |
IA0058 # 05 Y:1993 | 05 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $13,994 | $250 | Implemented |
IA0058 # 04 Y:1993 | 04 | 1993 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $88,602 | $95,000 | Not Implemented |
IA0058 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,091 | $4,600 | Implemented |