Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
122
matching recommendationsSIC | 204 | Grain Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0427 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,798 | $828 | Not Implemented |
KU0427 # 04 Y:1994 | 04 | 1994 | TURN OFF STEAM TRACING DURING MILD WEATHER | $876 | $2,400 | Not Implemented |
KU0427 # 05 Y:1994 | 05 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $348 | $100 | Not Implemented |
KU0427 # 06 Y:1994 | 06 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $160 | $107 | Implemented |
KU0427 # 07 Y:1994 | 07 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,234 | $7,537 | Implemented |
KU0278 # 01 Y:1989 | 01 | 1989 | INSULATE BARE EQUIPMENT | $325 | $600 | Implemented |
KU0278 # 02 Y:1989 | 02 | 1989 | INSULATE BARE EQUIPMENT | $531 | $500 | Not Implemented |
KU0278 # 03 Y:1989 | 03 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $472 | $600 | Implemented |
KU0278 # 04 Y:1989 | 04 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $295 | $400 | Implemented |
KU0278 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,914 | $6,334 | Implemented |
KU0278 # 06 Y:1989 | 06 | 1989 | IMPROVE LUBRICATION PRACTICES | $802 | $0 | Not Implemented |
KU0278 # 07 Y:1989 | 07 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,384 | $2,150 | Implemented |
KU0278 # 08 Y:1989 | 08 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $913 | $0 | Implemented |
KU0278 # 09 Y:1989 | 09 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,213 | $2,650 | Implemented |
KU0278 # 10 Y:1989 | 10 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $245 | $200 | Implemented |
KU0216 # 01 Y:1987 | 01 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $21,533 | $20,000 | Implemented |
KU0216 # 02 Y:1987 | 02 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,014 | $15,000 | Not Implemented |
KU0216 # 03 Y:1987 | 03 | 1987 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $6,934 | $9,000 | Not Implemented |
KU0216 # 04 Y:1987 | 04 | 1987 | INSTALL SET-BACK TIMERS | $2,429 | $683 | Implemented |
KU0216 # 05 Y:1987 | 05 | 1987 | IMPROVE LUBRICATION PRACTICES | $2,386 | $2,250 | Implemented |
KU0216 # 06 Y:1987 | 06 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,562 | $0 | Implemented |
KU0216 # 07 Y:1987 | 07 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,128 | $200 | Not Implemented |
KU0183 # 01 Y:1986 | 01 | 1986 | INSTALL SET-BACK TIMERS | $4,326 | $4,279 | Implemented |
KU0183 # 02 Y:1986 | 02 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,048 | $6,000 | Not Implemented |
KU0183 # 03 Y:1986 | 03 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,213 | $0 | Implemented |