Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

52

matching recommendations
Reset
SIC 205 Bakery Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IP0172 # 05 Y:2023 05 2023 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,584 $8,088 Not Implemented
IP0172 # 04 Y:2023 04 2023 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $14,315 $14,588 Not Implemented
IP0172 # 03 Y:2023 03 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,870 $1,313 Not Implemented
IP0172 # 02 Y:2023 02 2023 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS $512 $83 Not Implemented
IP0172 # 01 Y:2023 01 2023 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,640 $132 Not Implemented
IP0133 # 02 Y:2020 02 2020 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $2,073 $1,218 Not Implemented
IP0133 # 01 Y:2020 01 2020 INSTALL OCCUPANCY SENSORS $1,574 $343 Not Implemented
IP0133 # 04 Y:2020 04 2020 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $618 $553 Not Implemented
IP0133 # 03 Y:2020 03 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,033 $14,189 Not Implemented
IP0133 # 05 Y:2020 05 2020 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $2,196 $4,991 Not Implemented
IP0048 # 05 Y:2015 05 2015 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,880 $430 Implemented
IP0048 # 10 Y:2015 10 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $116 $413 Implemented
IP0048 # 09 Y:2015 09 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,176 $8,753 Implemented
IP0048 # 08 Y:2015 08 2015 APPLY FOR INVESTMENT INCENTIVES $15,491 $9,000 Not Implemented
IP0048 # 07 Y:2015 07 2015 APPLY FOR INVESTMENT INCENTIVES $8,854 $4,500 Not Implemented
IP0048 # 06 Y:2015 06 2015 AIR CONDITION ONLY SPACE NECESSARY $394 $193 Not Implemented
IP0048 # 04 Y:2015 04 2015 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $902 $45 Implemented
IP0048 # 03 Y:2015 03 2015 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,718 $5 Implemented
IP0048 # 02 Y:2015 02 2015 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $16,379 $5 Implemented
IP0048 # 01 Y:2015 01 2015 COMBINE UTILITY METERS $27,805 $21 Not Implemented
IP0047 # 09 Y:2015 09 2015 OPTIMIZE PLANT POWER FACTOR $5,199 $23,927 Not Implemented
IP0047 # 06 Y:2015 06 2015 APPLY FOR INVESTMENT INCENTIVES $10,288 $5,000 Implemented
IP0047 # 05 Y:2015 05 2015 APPLY FOR INVESTMENT INCENTIVES $30,801 $10,000 Implemented
IP0047 # 04 Y:2015 04 2015 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,968 $623 Not Implemented
IP0047 # 03 Y:2015 03 2015 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,543 $900 Not Implemented