Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
38
matching recommendationsSIC | 207 | Fats And Oils |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LS2421 # 05 Y:2024 | 05 | 2024 | LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS | $21,228 | $141,000 | n/a |
LS2421 # 04 Y:2024 | 04 | 2024 | INSTALL WIND POWERED ELECTRIC GENERATOR | $148,851 | $560,000 | n/a |
LS2421 # 01 Y:2024 | 01 | 2024 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $33,742 | $15,900 | n/a |
LS2421 # 02 Y:2024 | 02 | 2024 | UPGRADE CONTROLS ON COMPRESSORS | $8,504 | $12,500 | n/a |
LS2421 # 03 Y:2024 | 03 | 2024 | USE OTHER WASTE CONCENTRATION METHODS | $590,512 | $783,539 | n/a |
LL0361 # 01 Y:2011 | 01 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,242 | $540 | Not Implemented |
LL0361 # 02 Y:2011 | 02 | 2011 | USE PHOTOCELL CONTROLS | $1,052 | $120 | Not Implemented |
LL0361 # 03 Y:2011 | 03 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $868 | $625 | Not Implemented |
LL0361 # 04 Y:2011 | 04 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $561 | $90 | Not Implemented |
LL0361 # 05 Y:2011 | 05 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $326 | $368 | Not Implemented |
LL0361 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $306 | $175 | Not Implemented |
LL0361 # 07 Y:2011 | 07 | 2011 | INSTALL OCCUPANCY SENSORS | $209 | $900 | Not Implemented |
LL0361 # 08 Y:2011 | 08 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $165 | $75 | Not Implemented |
LL0361 # 09 Y:2011 | 09 | 2011 | INSULATE BARE EQUIPMENT | $85 | $345 | Not Implemented |
LL0360 # 04 Y:2011 | 04 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,635 | $810 | Not Implemented |
LL0360 # 01 Y:2011 | 01 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $627,674 | $22,250 | Implemented |
LL0360 # 03 Y:2011 | 03 | 2011 | INSULATE BARE EQUIPMENT | $16,577 | $1,321 | Implemented |
LL0360 # 08 Y:2011 | 08 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $530 | $919 | Not Implemented |
LL0360 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,259 | $3,570 | Implemented |
LL0360 # 02 Y:2011 | 02 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $25,792 | $5,600 | Not Implemented |
LL0360 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,513 | $1,050 | Implemented |
LL0360 # 05 Y:2011 | 05 | 2011 | INSTALL OCCUPANCY SENSORS | $1,746 | $4,980 | Not Implemented |
LL0360 # 09 Y:2011 | 09 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $378 | $390 | Implemented |
LL0198 # 03 Y:2004 | 03 | 2004 | USE PHOTOCELL CONTROLS | $5,421 | $180 | Implemented |
LL0198 # 04 Y:2004 | 04 | 2004 | INSULATE BARE EQUIPMENT | $4,981 | $942 | Not Implemented |