Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
110
matching recommendationsSIC | 2077 | Animal And Marine Fats And Oils |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0361 # 07 Y:2011 | 07 | 2011 | INSTALL OCCUPANCY SENSORS | $209 | $900 | Not Implemented |
LL0361 # 08 Y:2011 | 08 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $165 | $75 | Not Implemented |
LL0361 # 09 Y:2011 | 09 | 2011 | INSULATE BARE EQUIPMENT | $85 | $345 | Not Implemented |
MS0353 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $1,522,531 | $8,282,000 | Not Implemented |
MS0353 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $34,831 | $57,360 | Implemented |
MS0353 # 03 Y:2010 | 03 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $19,240 | $312 | Implemented |
MS0353 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,131 | $322 | Implemented |
MS0353 # 05 Y:2010 | 05 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,266 | $1,050 | Not Implemented |
WV0277 # 01 Y:2003 | 01 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $110,201 | $2,195 | Not Implemented |
WV0277 # 02 Y:2003 | 02 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,711 | $1,000 | Implemented |
WV0277 # 03 Y:2003 | 03 | 2003 | MINIMIZE WATER USAGE | $56,297 | $17,800 | Not Implemented |
WV0277 # 04 Y:2003 | 04 | 2003 | RECOVER AND REUSE WASTE MATERIAL | $65,102 | $250,000 | Not Implemented |
WV0277 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $61,699 | $29,824 | Implemented |
WV0277 # 06 Y:2003 | 06 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $40,926 | $450 | Implemented |
WV0277 # 07 Y:2003 | 07 | 2003 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $40,046 | $1,050 | Implemented |
WV0277 # 08 Y:2003 | 08 | 2003 | OPTIMIZE PLANT POWER FACTOR | $10,739 | $62,060 | Implemented |
WV0277 # 09 Y:2003 | 09 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,204 | $5,175 | Implemented |
WV0277 # 10 Y:2003 | 10 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,044 | $0 | Not Implemented |
WV0277 # 11 Y:2003 | 11 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,257 | $70 | Implemented |
WV0277 # 12 Y:2003 | 12 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $931 | $470 | Not Implemented |
WI0424 # 01 Y:2002 | 01 | 2002 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $177,300 | $0 | Implemented |
WI0424 # 02 Y:2002 | 02 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,921 | $0 | Implemented |
WI0424 # 03 Y:2002 | 03 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,624 | $0 | Implemented |
WI0424 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $1,745 | $0 | Implemented |
MS0089 # 01 Y:1997 | 01 | 1997 | OPTIMIZE PLANT POWER FACTOR | $6,352 | $9,450 | n/a |