Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15
matching recommendationsSIC | 2085 | Distilled And Blended Liquors |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0972 # 01 Y:2017 | 01 | 2017 | COMBINE UTILITY METERS | $1,370 | $0 | Not Implemented |
UD0972 # 02 Y:2017 | 02 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,897 | $0 | Implemented |
UD0972 # 03 Y:2017 | 03 | 2017 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,800 | $3,250 | Implemented |
UD0972 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,266 | $7,210 | Implemented |
UD0972 # 05 Y:2017 | 05 | 2017 | USE PHOTOCELL CONTROLS | $3,473 | $1,550 | Not Implemented |
UD0972 # 06 Y:2017 | 06 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,488 | $300 | Implemented |
UD0972 # 07 Y:2017 | 07 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $454 | $1,400 | Not Implemented |
UD0553 # 01 Y:1998 | 01 | 1998 | IMPROVED MATERIAL HANDLING (MIXING AND TRANSFER) | $21,875 | $500 | Not Implemented |
UD0553 # 02 Y:1998 | 02 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $14,410 | $12,100 | Not Implemented |
UD0553 # 03 Y:1998 | 03 | 1998 | USE PLASTIC PALLETS INSTEAD OF WOOD | $5,600 | $0 | Not Implemented |
UD0553 # 04 Y:1998 | 04 | 1998 | INSTALL COMMON HEADER ON COMPRESSORS | $12,000 | $2,000 | Not Implemented |
UD0553 # 05 Y:1998 | 05 | 1998 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,947 | $10,000 | Not Implemented |
UD0553 # 06 Y:1998 | 06 | 1998 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $8,274 | $1,000 | Not Implemented |
UD0553 # 07 Y:1998 | 07 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,594 | $13,677 | Not Implemented |
UD0553 # 08 Y:1998 | 08 | 1998 | UPGRADE CONTROLS ON COMPRESSORS | $5,271 | $800 | Implemented |