Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
233
matching recommendationsSIC | 2086 | Bottled And Canned Soft Drinks |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0316 # 08 Y:2017 | 08 | 2017 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,115 | $18,100 | Not Implemented |
MI0316 # 06 Y:2017 | 06 | 2017 | INSTALL OCCUPANCY SENSORS | $10,816 | $7,881 | Implemented |
MI0316 # 04 Y:2017 | 04 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,732 | $1,660 | Implemented |
MI0316 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,854 | $61,030 | Implemented |
MI0316 # 02 Y:2017 | 02 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $72,034 | $39,216 | Implemented |
MI0316 # 01 Y:2017 | 01 | 2017 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $313,428 | $142,400 | Not Implemented |
MI0316 # 07 Y:2017 | 07 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,887 | $4,577 | Not Implemented |
MI0279 # 05 Y:2015 | 05 | 2015 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,141 | $2,100 | Implemented |
MI0279 # 01 Y:2015 | 01 | 2015 | INCREASE EFFICIENCY OF TRUCKS | $30,426 | $29,000 | Not Implemented |
MI0279 # 02 Y:2015 | 02 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $29,100 | $80,000 | Not Implemented |
MI0279 # 03 Y:2015 | 03 | 2015 | RECOVER AND REUSE COOLING WATER | $12,134 | $497 | Implemented |
MI0279 # 04 Y:2015 | 04 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $11,413 | $12,060 | Implemented |
MI0279 # 06 Y:2015 | 06 | 2015 | USE OPTIMUM THICKNESS INSULATION | $4,666 | $1,810 | Implemented |
MI0279 # 07 Y:2015 | 07 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,329 | $40 | Implemented |
MI0279 # 09 Y:2015 | 09 | 2015 | INSULATE BARE EQUIPMENT | $1,612 | $482 | Implemented |
MI0279 # 08 Y:2015 | 08 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,877 | $2,520 | Implemented |
MI0279 # 13 Y:2015 | 13 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $634 | $1,760 | Implemented |
MI0279 # 12 Y:2015 | 12 | 2015 | USE PHOTOCELL CONTROLS | $1,139 | $480 | Implemented |
MI0279 # 10 Y:2015 | 10 | 2015 | INSTALL OCCUPANCY SENSORS | $1,456 | $1,782 | Not Implemented |
MI0279 # 11 Y:2015 | 11 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,317 | $3,280 | Not Implemented |
UF0440 # 06 Y:2011 | 06 | 2011 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $136 | $244 | Not Implemented |
UF0440 # 07 Y:2011 | 07 | 2011 | INSTALL TURBULATORS | $3,745 | $3,750 | Not Implemented |
UF0440 # 08 Y:2011 | 08 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,493 | $9,387 | Not Implemented |
UF0440 # 09 Y:2011 | 09 | 2011 | INSTALL OCCUPANCY SENSORS | $2,620 | $243 | Not Implemented |
UF0440 # 10 Y:2011 | 10 | 2011 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $635 | $0 | Not Implemented |