Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

474

matching recommendations
Reset
SIC 2092 Fresh Or Frozen Prepared Fish
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0028 # 03 Y:1995 03 1995 INSTALL TIMERS AND/OR THERMOSTATS $3,234 $450 Not Implemented
MS0028 # 04 Y:1995 04 1995 INSTALL TIMERS AND/OR THERMOSTATS $1,146 $1,050 Not Implemented
MS0028 # 05 Y:1995 05 1995 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $225 $100 Implemented
OR0213 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $388 $2,028 Implemented
OR0213 # 02 Y:1994 02 1994 OPTIMIZE PLANT POWER FACTOR $5,154 $6,500 Not Implemented
OR0213 # 03 Y:1994 03 1994 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,889 $6,000 Not Implemented
OR0215 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $201 $641 Implemented
OR0215 # 02 Y:1994 02 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $71 $383 Not Implemented
OR0215 # 03 Y:1994 03 1994 OPTIMIZE PLANT POWER FACTOR $2,626 $2,800 Not Implemented
OR0215 # 04 Y:1994 04 1994 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $207 $1,667 Not Implemented
OR0215 # 05 Y:1994 05 1994 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $652 $500 Implemented
KG0006 # 01 Y:1994 01 1994 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $66,725 $1,260 Not Implemented
KG0006 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,688 $9,480 Implemented
KG0006 # 03 Y:1994 03 1994 INSTALL TIMERS AND/OR THERMOSTATS $3,500 $1,350 Not Implemented
KG0006 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,449 $730 Implemented
KG0006 # 05 Y:1994 05 1994 INSULATE BARE EQUIPMENT $1,458 $270 Implemented
KG0006 # 06 Y:1994 06 1994 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,036 $3,700 Not Implemented
KG0006 # 07 Y:1994 07 1994 INSULATE BARE EQUIPMENT $972 $188 Implemented
UF0090 # 01 Y:1994 01 1994 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $3,450 $0 Implemented
UF0090 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $9,296 $19,877 Implemented
UF0090 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,852 $951 Implemented
UF0090 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,351 $8,499 Implemented
UF0090 # 05 Y:1994 05 1994 INSTALL SPECTRAL REFLECTORS / DELAMP $8,930 $9,403 Implemented
UF0090 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $379 $720 Not Implemented
UF0090 # 07 Y:1994 07 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,278 $4,190 Implemented