Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
13
matching recommendationsSIC | 2092 | Fresh Or Frozen Prepared Fish |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0169 # 01 Y:1993 | 01 | 1993 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $34,181 | $70,000 | Not Implemented |
WI0169 # 02 Y:1993 | 02 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,593 | $2,100 | Implemented |
WI0169 # 03 Y:1993 | 03 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,001 | $500 | Not Implemented |
WI0169 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $896 | $1,454 | Implemented |
WI0169 # 05 Y:1993 | 05 | 1993 | INSTALL OCCUPANCY SENSORS | $570 | $1,600 | Implemented |
WI0169 # 06 Y:1993 | 06 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $51 | $0 | Not Implemented |
WI0120 # 01 Y:1991 | 01 | 1991 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $2,372 | $500 | Not Implemented |
WI0120 # 02 Y:1991 | 02 | 1991 | RECOVER AND REUSE COOLING WATER | $1,504 | $6,000 | Not Implemented |
WI0120 # 03 Y:1991 | 03 | 1991 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $422 | $0 | Not Implemented |
WI0120 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $106 | $72 | Not Implemented |
WI0120 # 05 Y:1991 | 05 | 1991 | INSTALL SET-BACK TIMERS | $306 | $400 | Not Implemented |
WI0120 # 06 Y:1991 | 06 | 1991 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $442 | $1,120 | Not Implemented |
WI0120 # 07 Y:1991 | 07 | 1991 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $196 | $200 | Not Implemented |