IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

9

matching recommendations
Reset
SIC 2092 Fresh Or Frozen Prepared Fish
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ME0253 # 01 Y:1998 01 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $30,662 $83,099 Implemented
ME0253 # 02 Y:1998 02 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,977 $26,897 Implemented
ME0253 # 03 Y:1998 03 1998 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $12,878 $10,000 Implemented
ME0253 # 04 Y:1998 04 1998 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $12,836 $29,200 Not Implemented
ME0253 # 05 Y:1998 05 1998 REMOVE UNNEEDED SERVICE LINES TO ELIMINATE POTENTIAL LEAKS $1,600 $3,600 Not Implemented
ME0253 # 06 Y:1998 06 1998 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $1,571 $5,022 Implemented
ME0253 # 07 Y:1998 07 1998 PAY UTILITY BILLS ON TIME $1,227 $0 Implemented
ME0253 # 08 Y:1998 08 1998 $92,343 $1,105,000 Not Implemented
ME0253 # 09 Y:1998 09 1998 RECOVER AND REUSE COOLING WATER $1,436 $1,150 Not Implemented