Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsSIC | 2092 | Fresh Or Frozen Prepared Fish |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0215 # 05 Y:1994 | 05 | 1994 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $652 | $500 | Implemented |
OR0215 # 04 Y:1994 | 04 | 1994 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $207 | $1,667 | Not Implemented |
OR0215 # 03 Y:1994 | 03 | 1994 | OPTIMIZE PLANT POWER FACTOR | $2,626 | $2,800 | Not Implemented |
OR0215 # 02 Y:1994 | 02 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $71 | $383 | Not Implemented |
OR0215 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $201 | $641 | Implemented |
OR0213 # 03 Y:1994 | 03 | 1994 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,889 | $6,000 | Not Implemented |
OR0213 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $388 | $2,028 | Implemented |
OR0213 # 02 Y:1994 | 02 | 1994 | OPTIMIZE PLANT POWER FACTOR | $5,154 | $6,500 | Not Implemented |
KG0006 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,688 | $9,480 | Implemented |
KG0006 # 07 Y:1994 | 07 | 1994 | INSULATE BARE EQUIPMENT | $972 | $188 | Implemented |
KG0006 # 06 Y:1994 | 06 | 1994 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,036 | $3,700 | Not Implemented |
KG0006 # 05 Y:1994 | 05 | 1994 | INSULATE BARE EQUIPMENT | $1,458 | $270 | Implemented |
KG0006 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,449 | $730 | Implemented |
KG0006 # 03 Y:1994 | 03 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $3,500 | $1,350 | Not Implemented |
KG0006 # 01 Y:1994 | 01 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $66,725 | $1,260 | Not Implemented |
UF0090 # 01 Y:1994 | 01 | 1994 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $3,450 | $0 | Implemented |
UF0090 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,296 | $19,877 | Implemented |
UF0090 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,852 | $951 | Implemented |
UF0090 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,351 | $8,499 | Implemented |
UF0090 # 05 Y:1994 | 05 | 1994 | INSTALL SPECTRAL REFLECTORS / DELAMP | $8,930 | $9,403 | Implemented |
UF0090 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $379 | $720 | Not Implemented |
UF0090 # 07 Y:1994 | 07 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,278 | $4,190 | Implemented |
UF0090 # 08 Y:1994 | 08 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $738 | $1,000 | Not Implemented |
UF0090 # 09 Y:1994 | 09 | 1994 | HEAT WATER WITH EXHAUST HEAT | $5,098 | $1,800 | Not Implemented |
UF0090 # 10 Y:1994 | 10 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $21,205 | $75,000 | Not Implemented |