Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
21
matching recommendationsSIC | 2261 | Finishing Plants, Cotton |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0405 # 08 Y:1997 | 08 | 1997 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $531 | $600 | Not Implemented |
MA0405 # 07 Y:1997 | 07 | 1997 | MINIMIZE WATER USAGE | $1,049 | $2,125 | Not Implemented |
MA0405 # 06 Y:1997 | 06 | 1997 | INSTALL OCCUPANCY SENSORS | $1,335 | $1,620 | Implemented |
MA0405 # 01 Y:1997 | 01 | 1997 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $110,455 | $131,100 | Not Implemented |
MA0405 # 02 Y:1997 | 02 | 1997 | MINIMIZE WATER USAGE | $25,165 | $3,413 | Implemented |
MA0405 # 03 Y:1997 | 03 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,177 | $28,900 | Implemented |
MA0405 # 04 Y:1997 | 04 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,631 | $266 | Not Implemented |
MA0405 # 05 Y:1997 | 05 | 1997 | OPTIMIZE PLANT POWER FACTOR | $2,412 | $5,275 | Not Implemented |
OD0086 # 05 Y:1997 | 05 | 1997 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $594 | $0 | Not Implemented |
OD0086 # 04 Y:1997 | 04 | 1997 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $900 | $0 | Not Implemented |
OD0086 # 03 Y:1997 | 03 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,515 | $1,500 | Implemented |
OD0086 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,489 | $2,400 | Implemented |
OD0086 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $740 | $1,659 | Not Implemented |
MA0388 # 08 Y:1997 | 08 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $32,204 | $55,094 | Implemented |
MA0388 # 07 Y:1997 | 07 | 1997 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,002 | $0 | Implemented |
MA0388 # 06 Y:1997 | 06 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $604 | $272 | Implemented |
MA0388 # 05 Y:1997 | 05 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,406 | $858 | Not Implemented |
MA0388 # 04 Y:1997 | 04 | 1997 | USE MAGNETIC TECHNOLOGY TO TREAT WATER | $7,561 | $18,983 | Not Implemented |
MA0388 # 03 Y:1997 | 03 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,884 | $4,925 | Implemented |
MA0388 # 02 Y:1997 | 02 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,382 | $1,100 | Not Implemented |
MA0388 # 01 Y:1997 | 01 | 1997 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $95,807 | $47,527 | Implemented |