Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
26
matching recommendationsSIC | 232 | Men's And Boys' Furnishings, Work Clothing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0021 # 05 Y:2001 | 05 | 2001 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $3,250 | $4,200 | Implemented |
MI0021 # 04 Y:2001 | 04 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,275 | $7 | Not Implemented |
MI0021 # 03 Y:2001 | 03 | 2001 | MODIFY STARTUP/SHUTDOWN TIMES | $3,634 | $113 | Not Implemented |
MI0021 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,770 | $312 | Implemented |
MI0021 # 01 Y:2001 | 01 | 2001 | METER WASTE WATER | $13,904 | $3,650 | Not Implemented |
UF0017 # 06 Y:1992 | 06 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,928 | $669 | Not Implemented |
UF0016 # 06 Y:1992 | 06 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,132 | $1,000 | Implemented |
UF0016 # 05 Y:1992 | 05 | 1992 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $1,151 | $6,110 | Implemented |
UF0016 # 04 Y:1992 | 04 | 1992 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,664 | $7,280 | Not Implemented |
UF0016 # 03 Y:1992 | 03 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $186 | $3,965 | Implemented |
UF0016 # 02 Y:1992 | 02 | 1992 | INSTALL SPECTRAL REFLECTORS / DELAMP | $5,883 | $13,275 | Not Implemented |
UF0016 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,022 | $1,895 | Not Implemented |
UF0017 # 07 Y:1992 | 07 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $670 | $2,125 | Not Implemented |
UF0019 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,388 | $2,380 | Not Implemented |
UF0017 # 05 Y:1992 | 05 | 1992 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,192 | $8,374 | Not Implemented |
UF0017 # 04 Y:1992 | 04 | 1992 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $4,712 | $4,000 | Not Implemented |
UF0017 # 03 Y:1992 | 03 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $60 | $870 | Not Implemented |
UF0017 # 02 Y:1992 | 02 | 1992 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,525 | $14,685 | Not Implemented |
UF0017 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $741 | $731 | Not Implemented |
UF0019 # 08 Y:1992 | 08 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,879 | $6,854 | Not Implemented |
UF0019 # 07 Y:1992 | 07 | 1992 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $338 | $1,500 | Not Implemented |
UF0019 # 06 Y:1992 | 06 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,174 | $2,000 | Not Implemented |
UF0019 # 05 Y:1992 | 05 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $599 | $9,321 | Not Implemented |
UF0019 # 04 Y:1992 | 04 | 1992 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $16,213 | $10,220 | Not Implemented |
UF0019 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $798 | $8,466 | Not Implemented |