Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
46
matching recommendationsSIC | 239 | Misc. Fabricated Textile Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0542 # 04 Y:1995 | 04 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $459 | $0 | Implemented |
TN0488 # 06 Y:1993 | 06 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,637 | $0 | Implemented |
TN0488 # 05 Y:1993 | 05 | 1993 | USE SYNTHETIC LUBRICANT | $62 | $0 | Implemented |
TN0488 # 04 Y:1993 | 04 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $185 | $510 | Not Implemented |
TN0488 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $226 | $358 | Implemented |
TN0488 # 02 Y:1993 | 02 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $513 | $0 | Not Implemented |
TN0488 # 01 Y:1993 | 01 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $636 | $1,060 | Not Implemented |
TN0461 # 02 Y:1992 | 02 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,756 | $1,000 | Not Implemented |
TN0461 # 09 Y:1992 | 09 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $14,582 | $0 | Not Implemented |
TN0461 # 08 Y:1992 | 08 | 1992 | OPTIMIZE PLANT POWER FACTOR | $29,700 | $32,400 | Not Implemented |
TN0461 # 07 Y:1992 | 07 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $598 | $480 | Not Implemented |
TN0461 # 06 Y:1992 | 06 | 1992 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,178 | $0 | Not Implemented |
TN0461 # 05 Y:1992 | 05 | 1992 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,758 | $1,535 | Not Implemented |
TN0461 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,188 | $2,188 | Not Implemented |
TN0461 # 03 Y:1992 | 03 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,074 | $1,380 | Not Implemented |
TN0461 # 01 Y:1992 | 01 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $41,641 | $47,895 | Not Implemented |
TN0197 # 05 Y:1983 | 05 | 1983 | INCREASE AMOUNT OF CONDENSATE RETURNED | $10,626 | $27,000 | Not Implemented |
TN0197 # 04 Y:1983 | 04 | 1983 | INSULATE BARE EQUIPMENT | $1,620 | $634 | Not Implemented |
TN0197 # 03 Y:1983 | 03 | 1983 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $3,170 | $15,000 | Not Implemented |
TN0197 # 02 Y:1983 | 02 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $910 | $500 | Not Implemented |
TN0197 # 01 Y:1983 | 01 | 1983 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,035 | $500 | Not Implemented |