Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
116
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0072 # 03 Y:1983 | 03 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $3,142 | $100 | Not Implemented |
KU0072 # 04 Y:1983 | 04 | 1983 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $1,843 | $0 | Not Implemented |
KU0072 # 05 Y:1983 | 05 | 1983 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,160 | $837 | Not Implemented |
KU0072 # 06 Y:1983 | 06 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $269 | $200 | Not Implemented |
KU0072 # 07 Y:1983 | 07 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $537 | $200 | Not Implemented |
KU0072 # 08 Y:1983 | 08 | 1983 | INSTALL AUTOMATIC STACK DAMPER | $617 | $700 | Not Implemented |
KU0072 # 09 Y:1983 | 09 | 1983 | INSTALL AUTOMATIC STACK DAMPER | $537 | $528 | Not Implemented |
KU0055 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $311 | $520 | Implemented |
KU0055 # 02 Y:1982 | 02 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $28,915 | $1,400 | Not Implemented |
KU0055 # 03 Y:1982 | 03 | 1982 | KEEP SOLID FUELS / RAW MATERIALS DRY | $14,171 | $0 | Not Implemented |
KU0055 # 04 Y:1982 | 04 | 1982 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $15,482 | $500 | Implemented |
KU0055 # 05 Y:1982 | 05 | 1982 | OPTIMIZE PLANT POWER FACTOR | $2,061 | $1,800 | Implemented |
KU0055 # 06 Y:1982 | 06 | 1982 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $66,400 | $240,000 | Not Implemented |
KU0028 # 01 Y:1981 | 01 | 1981 | INSTALL TIMERS AND/OR THERMOSTATS | $325 | $0 | Not Implemented |
KU0028 # 02 Y:1981 | 02 | 1981 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,428 | $3,992 | Not Implemented |
KU0028 # 03 Y:1981 | 03 | 1981 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $298 | $0 | Not Implemented |