Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
65
matching recommendationsSIC | 249 | Miscellaneous Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LT8405 # 03 Y:2024 | 03 | 2024 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $29,983 | $78,432 | n/a |
LT8405 # 02 Y:2024 | 02 | 2024 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $14,646 | $48,894 | n/a |
LT8405 # 01 Y:2024 | 01 | 2024 | INSTALL OCCUPANCY SENSORS | $3,869 | $6,130 | n/a |
AM0728 # 10 Y:2017 | 10 | 2017 | USE SYNTHETIC LUBRICANT | $386 | $0 | Implemented |
AM0728 # 06 Y:2017 | 06 | 2017 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,100 | $1,070 | Implemented |
AM0728 # 05 Y:2017 | 05 | 2017 | USE PHOTOCELL CONTROLS | $2,740 | $140 | Implemented |
AM0728 # 04 Y:2017 | 04 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,530 | $1,000 | Implemented |
AM0728 # 03 Y:2017 | 03 | 2017 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $41,700 | $4,000 | Implemented |
AM0728 # 09 Y:2017 | 09 | 2017 | PAY UTILITY BILLS ON TIME | $676 | $0 | Implemented |
AM0728 # 02 Y:2017 | 02 | 2017 | OPTIMIZE PLANT POWER FACTOR | $8,480 | $5,420 | Implemented |
AM0728 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,680 | $20,300 | Implemented |
AM0728 # 08 Y:2017 | 08 | 2017 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $11,310 | $4,370 | Implemented |
AM0728 # 07 Y:2017 | 07 | 2017 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $7,250 | $1,000 | Implemented |
AM0647 # 07 Y:2013 | 07 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $115 | $32 | Implemented |
AM0647 # 01 Y:2013 | 01 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,640 | $34 | Implemented |
AM0647 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $450 | $25 | Implemented |
AM0647 # 02 Y:2013 | 02 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $6,475 | $0 | Implemented |
AM0647 # 04 Y:2013 | 04 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $645 | $240 | Implemented |
AM0647 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $280 | $600 | Implemented |
AM0647 # 03 Y:2013 | 03 | 2013 | USE SYNTHETIC LUBRICANT | $805 | $0 | Implemented |
AM0444 # 05 Y:2003 | 05 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,950 | $10,000 | Not Implemented |
AM0444 # 04 Y:2003 | 04 | 2003 | USE SYNTHETIC LUBRICANT | $280 | $0 | Not Implemented |
AM0444 # 03 Y:2003 | 03 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $390 | $80 | Implemented |
AM0444 # 01 Y:2003 | 01 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $11,800 | $0 | Implemented |
AM0444 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $460 | $200 | Implemented |