Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
22
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0094 # 08 Y:2013 | 08 | 2013 | DISCONNECT BALLASTS | $13,800 | $8,100 | Implemented |
UA0094 # 06 Y:2013 | 06 | 2013 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $6,212 | $16,350 | Implemented |
UA0094 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,674 | $4,500 | Implemented |
UA0094 # 03 Y:2013 | 03 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $12,165 | $800 | Implemented |
UA0094 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,672 | $4,500 | Implemented |
UA0094 # 01 Y:2013 | 01 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $52,762 | $41,601 | Implemented |
GT0787 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $550 | $550 | Implemented |
GT0787 # 01 Y:2004 | 01 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $20,920 | $13,200 | Implemented |
GT0697 # 05 Y:2000 | 05 | 2000 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $5,825 | $2,850 | Implemented |
GT0697 # 09 Y:2000 | 09 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $912 | $2,880 | Implemented |
GT0697 # 07 Y:2000 | 07 | 2000 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $19,000 | $3,800 | Implemented |
GT0697 # 04 Y:2000 | 04 | 2000 | INSTALL SENSORS TO DETECT DEFECTS | $38,825 | $600 | Implemented |
GT0697 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,385 | $46,235 | Implemented |
GT0505 # 07 Y:1993 | 07 | 1993 | USE RADIANT HEATER FOR SPOT HEATING | $11,700 | $80,000 | Implemented |
GT0505 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,250 | $830 | Implemented |
GT0505 # 02 Y:1993 | 02 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,370 | $6,400 | Implemented |
GT0505 # 01 Y:1993 | 01 | 1993 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,090 | $1,600 | Implemented |
GT0333 # 01 Y:1987 | 01 | 1987 | INSTALL SET-BACK TIMERS | $6,040 | $500 | Implemented |
GT0333 # 07 Y:1987 | 07 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $362 | $1,061 | Implemented |
GT0333 # 05 Y:1987 | 05 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,150 | $4,980 | Implemented |
GT0333 # 03 Y:1987 | 03 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $840 | $0 | Implemented |
GT0333 # 02 Y:1987 | 02 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $7,210 | $500 | Implemented |