Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsSIC | 25 | Furniture And Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
RU0073 # 07 Y:1989 | 07 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,530 | $44,000 | Not Implemented |
RU0073 # 06 Y:1989 | 06 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $278 | $0 | Implemented |
RU0073 # 05 Y:1989 | 05 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,635 | $645 | Implemented |
RU0073 # 04 Y:1989 | 04 | 1989 | AIR CONDITION ONLY SPACE NECESSARY | $846 | $0 | Not Implemented |
RU0073 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,227 | $2,028 | Implemented |
RU0073 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,131 | $325 | Implemented |
RU0073 # 01 Y:1989 | 01 | 1989 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,457 | $450 | Not Implemented |
RU0057 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,269 | $0 | Not Implemented |
RU0057 # 06 Y:1989 | 06 | 1989 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $807 | $0 | Not Implemented |
RU0057 # 05 Y:1989 | 05 | 1989 | IMPROVE LUBRICATION PRACTICES | $379 | $800 | Not Implemented |
RU0057 # 04 Y:1989 | 04 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $387 | $2,250 | Not Implemented |
RU0057 # 03 Y:1989 | 03 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,520 | $594 | Not Implemented |
RU0057 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,747 | $1,539 | Not Implemented |
RU0057 # 07 Y:1989 | 07 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,372 | $0 | Not Implemented |
ST0001 # 11 Y:1984 | 11 | 1984 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $934 | $0 | Not Implemented |
ST0001 # 10 Y:1984 | 10 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,345 | $0 | Not Implemented |
ST0001 # 09 Y:1984 | 09 | 1984 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,902 | $0 | Implemented |
ST0001 # 08 Y:1984 | 08 | 1984 | INSTALL AUTOMATIC STACK DAMPER | $923 | $658 | Not Implemented |
ST0001 # 07 Y:1984 | 07 | 1984 | AIR CONDITION ONLY SPACE NECESSARY | $846 | $675 | Implemented |
ST0001 # 06 Y:1984 | 06 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $300 | $65 | Not Implemented |
ST0001 # 05 Y:1984 | 05 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,130 | $3,299 | Implemented |
ST0001 # 04 Y:1984 | 04 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $13,166 | $0 | Not Implemented |
ST0001 # 03 Y:1984 | 03 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,350 | $88 | Implemented |
ST0001 # 02 Y:1984 | 02 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $692 | $537 | Implemented |
ST0001 # 01 Y:1984 | 01 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $31 | $0 | Implemented |