Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
242
matching recommendationsSIC | 2522 | Office Furniture, Except Wood |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0250 # 03 Y:1988 | 03 | 1988 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $520 | $60 | Not Implemented |
KU0250 # 04 Y:1988 | 04 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,679 | $2,000 | Implemented |
KU0250 # 05 Y:1988 | 05 | 1988 | INSTALL AUTOMATIC STACK DAMPER | $1,207 | $1,650 | Implemented |
KU0250 # 06 Y:1988 | 06 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $378 | $0 | Implemented |
KU0250 # 07 Y:1988 | 07 | 1988 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $316 | $0 | Implemented |
KU0250 # 08 Y:1988 | 08 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $260 | $0 | Implemented |
KU0250 # 09 Y:1988 | 09 | 1988 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $986 | $0 | Not Implemented |
TS0012 # 01 Y:1985 | 01 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $952 | $30 | Implemented |
TS0012 # 02 Y:1985 | 02 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $365 | $300 | Not Implemented |
TS0012 # 03 Y:1985 | 03 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $13,907 | $0 | Implemented |
TS0012 # 04 Y:1985 | 04 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,998 | $9,765 | Implemented |
UD0115 # 01 Y:1984 | 01 | 1984 | INSTALL STORM WINDOWS AND DOORS | $30,317 | $42,568 | Implemented |
UD0115 # 02 Y:1984 | 02 | 1984 | USE OPTIMUM TEMPERATURE | $662 | $1,000 | Implemented |
UD0115 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,093 | $239 | Implemented |
UD0115 # 04 Y:1984 | 04 | 1984 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $1,013 | $3,000 | Not Implemented |
UD0115 # 05 Y:1984 | 05 | 1984 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $5,490 | $35,000 | Not Implemented |
UD0115 # 06 Y:1984 | 06 | 1984 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $1,350 | $4,000 | Not Implemented |