IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20

matching recommendations
Reset
SIC 2522 Office Furniture, Except Wood
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0336 # 09 Y:1999 09 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $576 $740 Not Implemented
WI0336 # 08 Y:1999 08 1999 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $2,805 $8,400 Not Implemented
WI0336 # 07 Y:1999 07 1999 TREAT AND REUSE RINSE WATERS $4,813 $1,600 Not Implemented
WI0336 # 06 Y:1999 06 1999 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $5,640 $11,500 Not Implemented
WI0336 # 05 Y:1999 05 1999 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $8,244 $6,000 Not Implemented
WI0336 # 04 Y:1999 04 1999 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $10,632 $500 Not Implemented
WI0336 # 03 Y:1999 03 1999 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $11,499 $0 Implemented
WI0336 # 02 Y:1999 02 1999 LEASE EQUIPMENT INSTEAD OF PURCHASING $22,800 $0 Implemented
WI0336 # 01 Y:1999 01 1999 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $192,652 $0 Not Implemented
WI0058 # 11 Y:1989 11 1989 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $639 $0 Not Implemented
WI0058 # 01 Y:1989 01 1989 INSTALL TIMERS AND/OR THERMOSTATS $20,838 $3,000 Implemented
WI0058 # 10 Y:1989 10 1989 INSTALL STORM WINDOWS AND DOORS $865 $1,334 Not Implemented
WI0058 # 09 Y:1989 09 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $668 $0 Implemented
WI0058 # 08 Y:1989 08 1989 TURN OFF EQUIPMENT WHEN NOT IN USE $1,395 $800 Not Implemented
WI0058 # 07 Y:1989 07 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,585 $1,500 Implemented
WI0058 # 06 Y:1989 06 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,523 $0 Implemented
WI0058 # 05 Y:1989 05 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,077 $500 Implemented
WI0058 # 04 Y:1989 04 1989 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,645 $4,200 Not Implemented
WI0058 # 03 Y:1989 03 1989 IMPROVE LUBRICATION PRACTICES $7,226 $0 Implemented
WI0058 # 02 Y:1989 02 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $6,185 $20,000 Not Implemented