Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
150
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0165 # 01 Y:1989 | 01 | 1989 | INSTALL SET-BACK TIMERS | $502 | $157 | Not Implemented |
RU0072 # 01 Y:1989 | 01 | 1989 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $34,166 | $0 | Not Implemented |
RU0072 # 06 Y:1989 | 06 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,923 | $400 | Implemented |
RU0072 # 05 Y:1989 | 05 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,337 | $2,400 | Implemented |
WI0072 # 08 Y:1989 | 08 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $165 | $0 | Not Implemented |
WI0072 # 01 Y:1989 | 01 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,236 | $0 | Implemented |
WI0072 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $564 | $3,238 | Not Implemented |
WI0072 # 03 Y:1989 | 03 | 1989 | IMPROVE LUBRICATION PRACTICES | $1,866 | $0 | Implemented |
WI0072 # 05 Y:1989 | 05 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $328 | $700 | Not Implemented |
WI0072 # 07 Y:1989 | 07 | 1989 | UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS | $283 | $400 | Not Implemented |
RU0064 # 08 Y:1989 | 08 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $3,059 | $800 | Implemented |
RU0068 # 02 Y:1989 | 02 | 1989 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,132 | $0 | Not Implemented |
RU0064 # 04 Y:1989 | 04 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $748 | $0 | Not Implemented |
RU0064 # 07 Y:1989 | 07 | 1989 | AIR CONDITION ONLY SPACE NECESSARY | $3,475 | $6,100 | Not Implemented |
RU0064 # 06 Y:1989 | 06 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,797 | $500 | Not Implemented |
MA0158 # 02 Y:1989 | 02 | 1989 | HEAT WATER WITH EXHAUST HEAT | $22,335 | $135,000 | Not Implemented |
RU0068 # 04 Y:1989 | 04 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $2,169 | $1,912 | Not Implemented |
RU0068 # 03 Y:1989 | 03 | 1989 | IMPROVE LUBRICATION PRACTICES | $548 | $500 | Implemented |
RU0064 # 05 Y:1989 | 05 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,848 | $6,800 | Not Implemented |
RU0064 # 03 Y:1989 | 03 | 1989 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,444 | $0 | Not Implemented |
RU0064 # 01 Y:1989 | 01 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,083 | $0 | Implemented |
RU0064 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,074 | $251 | Implemented |
RU0068 # 01 Y:1989 | 01 | 1989 | AIR CONDITION ONLY SPACE NECESSARY | $5,037 | $3,133 | Not Implemented |
MA0158 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,262 | $838 | Implemented |
MA0158 # 04 Y:1989 | 04 | 1989 | INSULATE BARE EQUIPMENT | $3,704 | $4,682 | Not Implemented |