IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

7,948

matching recommendations
Reset
SIC 26 Paper And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0538 # 09 Y:1994 09 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $228,100 $770,000 Not Implemented
WV0038 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,370 $3,491 Implemented
WV0038 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,081 $118,620 Implemented
WV0038 # 03 Y:1994 03 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $32,800 $5,000 Not Implemented
WV0038 # 04 Y:1994 04 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $81,877 $4,570 Not Implemented
WV0038 # 05 Y:1994 05 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,334 $0 Implemented
WV0038 # 06 Y:1994 06 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $962 $150 Not Implemented
WV0038 # 07 Y:1994 07 1994 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $807 $0 Implemented
WV0038 # 08 Y:1994 08 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $7,763 $1,001 Not Implemented
OK0447 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,233 $8,800 Implemented
OK0447 # 02 Y:1994 02 1994 INSULATE BARE EQUIPMENT $505 $526 Implemented
OK0447 # 03 Y:1994 03 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,645 $0 Not Implemented
OK0447 # 04 Y:1994 04 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,581 $2,618 Not Implemented
OK0447 # 05 Y:1994 05 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,652 $832 Implemented
OK0447 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $815 $2,199 Implemented
OK0447 # 07 Y:1994 07 1994 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $43,497 $198,000 Not Implemented
CO0305 # 01 Y:1994 01 1994 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $16,210 $210,000 Implemented
CO0305 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,440 $6,760 Implemented
CO0305 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,830 $2,600 Not Implemented
CO0305 # 04 Y:1994 04 1994 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $3,550 $10,000 Not Implemented
CO0305 # 05 Y:1994 05 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,270 $4,330 Not Implemented
CO0305 # 06 Y:1994 06 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,160 $590 Implemented
CO0305 # 07 Y:1994 07 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,780 $370 Implemented
CO0305 # 08 Y:1994 08 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,255 $7,730 Not Implemented
CO0305 # 09 Y:1994 09 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,010 $30 Not Implemented