Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,948
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0043 # 07 Y:1988 | 07 | 1988 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,343 | $6,900 | Implemented |
RU0038 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,542 | $2,386 | Implemented |
RU0038 # 02 Y:1988 | 02 | 1988 | INSTALL SET-BACK TIMERS | $6,581 | $0 | Implemented |
RU0038 # 03 Y:1988 | 03 | 1988 | IMPROVE LUBRICATION PRACTICES | $874 | $1,600 | Not Implemented |
RU0038 # 04 Y:1988 | 04 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,137 | $72 | Not Implemented |
RU0038 # 05 Y:1988 | 05 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,757 | $0 | Implemented |
RU0038 # 06 Y:1988 | 06 | 1988 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,115 | $0 | Implemented |
RU0038 # 07 Y:1988 | 07 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,864 | $5,019 | Not Implemented |
RU0038 # 08 Y:1988 | 08 | 1988 | TURN OFF EQUIPMENT WHEN NOT IN USE | $279 | $800 | Implemented |
RU0038 # 09 Y:1988 | 09 | 1988 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,548 | $4,140 | Not Implemented |
RU0038 # 10 Y:1988 | 10 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $3,707 | $2,151 | Not Implemented |
RU0038 # 11 Y:1988 | 11 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,536 | $500 | Implemented |
MA0127 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,207 | $2,710 | Implemented |
MA0127 # 02 Y:1988 | 02 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,242 | $386 | Not Implemented |
MA0127 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $38,184 | $11,762 | Not Implemented |
MA0127 # 04 Y:1988 | 04 | 1988 | INSTALL SET-BACK TIMERS | $325 | $446 | Not Implemented |
MA0127 # 05 Y:1988 | 05 | 1988 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $872 | $240 | Not Implemented |
MA0127 # 06 Y:1988 | 06 | 1988 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $21,158 | $0 | Not Implemented |
MA0127 # 07 Y:1988 | 07 | 1988 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $170 | $0 | Implemented |
MA0127 # 08 Y:1988 | 08 | 1988 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $26,805 | $31,196 | Not Implemented |
KU0263 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,737 | $5,000 | Implemented |
KU0263 # 02 Y:1988 | 02 | 1988 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,188 | $4,000 | Not Implemented |
KU0263 # 03 Y:1988 | 03 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,211 | $1,600 | Implemented |
KU0263 # 04 Y:1988 | 04 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,486 | $1,308 | Implemented |
KU0263 # 05 Y:1988 | 05 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $219 | $0 | Implemented |