Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
40
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0196 # 01 Y:1983 | 01 | 1983 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,218 | $150 | Not Implemented |
TN0186 # 01 Y:1983 | 01 | 1983 | OPTIMIZE PLANT POWER FACTOR | $1,180 | $27,000 | Not Implemented |
TN0196 # 02 Y:1983 | 02 | 1983 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $47 | $0 | Not Implemented |
TN0186 # 02 Y:1983 | 02 | 1983 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,100 | $800 | Not Implemented |
TN0191 # 01 Y:1983 | 01 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,027 | $10,000 | Implemented |
TN0191 # 02 Y:1983 | 02 | 1983 | USE RADIANT HEATER FOR SPOT HEATING | $3,251 | $5,000 | Implemented |
UD0097 # 02 Y:1983 | 02 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,662 | $4,514 | Not Implemented |
UD0097 # 01 Y:1983 | 01 | 1983 | INSTALL STORM WINDOWS AND DOORS | $6,434 | $6,887 | Not Implemented |
KU0098 # 08 Y:1983 | 08 | 1983 | AIR CONDITION ONLY SPACE NECESSARY | $4,385 | $0 | Not Implemented |
KU0099 # 04 Y:1983 | 04 | 1983 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $544 | $0 | Implemented |
KU0099 # 03 Y:1983 | 03 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $628 | $660 | Implemented |
KU0099 # 02 Y:1983 | 02 | 1983 | INSTALL AUTOMATIC STACK DAMPER | $935 | $2,350 | Implemented |
KU0099 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,778 | $2,585 | Implemented |
KU0098 # 12 Y:1983 | 12 | 1983 | INSTALL SET-BACK TIMERS | $2,264 | $0 | Not Implemented |
KU0098 # 11 Y:1983 | 11 | 1983 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,711 | $0 | Not Implemented |
KU0098 # 10 Y:1983 | 10 | 1983 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $6,750 | $7,400 | Not Implemented |
KU0098 # 09 Y:1983 | 09 | 1983 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $360 | $252 | Not Implemented |
KU0098 # 07 Y:1983 | 07 | 1983 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $2,452 | $300 | Not Implemented |
KU0098 # 06 Y:1983 | 06 | 1983 | INSTALL AUTOMATIC STACK DAMPER | $1,331 | $1,700 | Not Implemented |
KU0098 # 05 Y:1983 | 05 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $580 | $510 | Not Implemented |
KU0098 # 04 Y:1983 | 04 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $615 | $300 | Not Implemented |
KU0098 # 03 Y:1983 | 03 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $2,886 | $162 | Not Implemented |
KU0098 # 02 Y:1983 | 02 | 1983 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,062 | $371 | Implemented |
KU0098 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,556 | $8,044 | Not Implemented |
UD0080 # 02 Y:1983 | 02 | 1983 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $13,125 | $53,100 | Not Implemented |