IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,551

matching recommendations
Reset
SIC 265 Paperboard Containers And Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MO0125 # 11 Y:1994 11 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $719 $330 Implemented
MO0120 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,763 $9,087 Implemented
MO0120 # 02 Y:1994 02 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,462 $280 Implemented
MO0120 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,946 $5,748 Implemented
MO0120 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,024 $253 Implemented
MO0120 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $185 $52 Not Implemented
MO0120 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $115 $332 Not Implemented
MO0120 # 07 Y:1994 07 1994 ADJUST VENTS TO MINIMIZE ENERGY USE $3,153 $2,727 Not Implemented
MO0120 # 08 Y:1994 08 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $968 $425 Not Implemented
MO0120 # 09 Y:1994 09 1994 USE SYNTHETIC LUBRICANT $549 $256 Not Implemented
MO0120 # 10 Y:1994 10 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $902 $1,575 Not Implemented
WI0209 # 01 Y:1994 01 1994 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $15,775 $23,025 Implemented
WI0209 # 02 Y:1994 02 1994 SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS $7,285 $0 Not Implemented
WI0209 # 03 Y:1994 03 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,192 $32,000 Not Implemented
WI0209 # 04 Y:1994 04 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,085 $500 Implemented
WI0209 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,164 $6,191 Not Implemented
WI0209 # 06 Y:1994 06 1994 INSTALL OCCUPANCY SENSORS $2,219 $1,125 Not Implemented
WI0209 # 07 Y:1994 07 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,673 $960 Not Implemented
WI0209 # 08 Y:1994 08 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,264 $1,167 Not Implemented
WI0209 # 09 Y:1994 09 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $549 $0 Not Implemented
OK0447 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,233 $8,800 Implemented
OK0447 # 02 Y:1994 02 1994 INSULATE BARE EQUIPMENT $505 $526 Implemented
OK0447 # 03 Y:1994 03 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,645 $0 Not Implemented
OK0447 # 04 Y:1994 04 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,581 $2,618 Not Implemented
OK0447 # 05 Y:1994 05 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,652 $832 Implemented