IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

263

matching recommendations
Reset
SIC 265 Paperboard Containers And Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0086 # 06 Y:1990 06 1990 INSTALL TIMERS AND/OR THERMOSTATS $799 $250 Not Implemented
WI0086 # 07 Y:1990 07 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $679 $500 Not Implemented
WI0086 # 08 Y:1990 08 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $508 $2,000 Not Implemented
WI0072 # 01 Y:1989 01 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,236 $0 Implemented
WI0072 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $564 $3,238 Not Implemented
WI0072 # 03 Y:1989 03 1989 IMPROVE LUBRICATION PRACTICES $1,866 $0 Implemented
WI0072 # 04 Y:1989 04 1989 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,052 $1,000 Not Implemented
WI0072 # 05 Y:1989 05 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $328 $700 Not Implemented
WI0072 # 06 Y:1989 06 1989 INSTALL TIMERS AND/OR THERMOSTATS $301 $250 Implemented
WI0072 # 07 Y:1989 07 1989 UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS $283 $400 Not Implemented
WI0072 # 08 Y:1989 08 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $165 $0 Not Implemented
WI0072 # 09 Y:1989 09 1989 SHUT OFF PILOTS IN STANDBY EQUIPMENT $133 $0 Implemented
WI0072 # 10 Y:1989 10 1989 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $730 $0 Not Implemented