Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,534

matching recommendations
Reset
SIC 265 Paperboard Containers And Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0068 # 05 Y:1983 05 1983 OPTIMIZE PLANT POWER FACTOR $3,507 $1,685 Implemented
KU0068 # 06 Y:1983 06 1983 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $1,291 $0 Not Implemented
UD0078 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,461 $238 Not Implemented
UD0078 # 02 Y:1983 02 1983 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $16,479 $50,000 Not Implemented
UD0078 # 03 Y:1983 03 1983 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $13,460 $33,725 Not Implemented
KU0068 # 07 Y:1983 07 1983 REDUCE VENTILATION AIR $3,114 $0 Not Implemented
KU0068 # 08 Y:1983 08 1983 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,464 $0 Not Implemented
KU0068 # 09 Y:1983 09 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $575 $358 Implemented
TN0159 # 01 Y:1982 01 1982 INSTALL / REPAIR INSULATION ON STEAM LINES $3,652 $578 Not Implemented
TN0159 # 02 Y:1982 02 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,463 $100 Not Implemented
TN0159 # 03 Y:1982 03 1982 INSTALL SET-BACK TIMERS $1,257 $0 Not Implemented
TN0161 # 01 Y:1982 01 1982 REPLACE BOILER $13,594 $80,000 Not Implemented
TN0161 # 02 Y:1982 02 1982 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $19,730 $20,000 Not Implemented
TN0161 # 03 Y:1982 03 1982 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $774 $0 Not Implemented
TN0161 # 04 Y:1982 04 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $774 $2,490 Not Implemented
GT0140 # 01 Y:1982 01 1982 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $445 $1,115 Not Implemented
GT0140 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $3,443 $0 Not Implemented
GT0140 # 03 Y:1982 03 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $814 $1,500 Not Implemented
KU0066 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,340 $3,302 Implemented
KU0066 # 02 Y:1982 02 1982 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,820 $0 Implemented
KU0066 # 03 Y:1982 03 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $957 $1,579 Implemented
KU0066 # 04 Y:1982 04 1982 INSTALL AUTOMATIC STACK DAMPER $560 $582 Implemented
KU0066 # 05 Y:1982 05 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $341 $200 Implemented
KU0066 # 06 Y:1982 06 1982 OPTIMIZE PLANT POWER FACTOR $1,172 $2,350 Not Implemented
KU0063 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,441 $5,865 Not Implemented