Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

187

matching recommendations
Reset
SIC 265 Paperboard Containers And Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0098 # 10 Y:1983 10 1983 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $6,750 $7,400 Not Implemented
KU0098 # 11 Y:1983 11 1983 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,711 $0 Not Implemented
KU0098 # 12 Y:1983 12 1983 INSTALL SET-BACK TIMERS $2,264 $0 Not Implemented
KU0068 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $20,263 $6,058 Implemented
KU0068 # 02 Y:1983 02 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $12,920 $6,931 Implemented
KU0068 # 03 Y:1983 03 1983 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,647 $20,000 Implemented
KU0068 # 04 Y:1983 04 1983 INSTALL TIMERS AND/OR THERMOSTATS $3,656 $149 Implemented
KU0068 # 05 Y:1983 05 1983 OPTIMIZE PLANT POWER FACTOR $3,507 $1,685 Implemented
KU0068 # 06 Y:1983 06 1983 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $1,291 $0 Not Implemented
KU0068 # 07 Y:1983 07 1983 REDUCE VENTILATION AIR $3,114 $0 Not Implemented
KU0068 # 08 Y:1983 08 1983 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,464 $0 Not Implemented
KU0068 # 09 Y:1983 09 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $575 $358 Implemented
KU0066 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,340 $3,302 Implemented
KU0066 # 02 Y:1982 02 1982 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,820 $0 Implemented
KU0066 # 03 Y:1982 03 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $957 $1,579 Implemented
KU0066 # 04 Y:1982 04 1982 INSTALL AUTOMATIC STACK DAMPER $560 $582 Implemented
KU0066 # 05 Y:1982 05 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $341 $200 Implemented
KU0066 # 06 Y:1982 06 1982 OPTIMIZE PLANT POWER FACTOR $1,172 $2,350 Not Implemented
KU0063 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,441 $5,865 Not Implemented
KU0063 # 02 Y:1982 02 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,532 $230,000 Implemented
KU0063 # 03 Y:1982 03 1982 OPTIMIZE PLANT POWER FACTOR $2,215 $4,000 Not Implemented
KU0063 # 04 Y:1982 04 1982 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $670 $0 Not Implemented
KU0063 # 05 Y:1982 05 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $173 $82 Implemented
KU0063 # 06 Y:1982 06 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,276 $450 Not Implemented
KU0063 # 07 Y:1982 07 1982 INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK $17,053 $57,400 Not Implemented