Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,551
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0100 # 07 Y:1994 | 07 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,274 | $1,680 | Implemented |
IA0100 # 08 Y:1994 | 08 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,056 | $12,220 | Implemented |
IA0100 # 09 Y:1994 | 09 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,880 | $5,000 | Implemented |
IA0100 # 10 Y:1994 | 10 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $761 | $475 | Implemented |
IA0100 # 11 Y:1994 | 11 | 1994 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,016 | $250 | Not Implemented |
KU0449 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,585 | $33,602 | Implemented |
KU0449 # 02 Y:1994 | 02 | 1994 | INSULATE BARE EQUIPMENT | $3,928 | $2,300 | Implemented |
KU0449 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,732 | $5,282 | Implemented |
KU0449 # 04 Y:1994 | 04 | 1994 | INSTALL SKYLIGHTS | $3,669 | $14,540 | Not Implemented |
KU0449 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,571 | $3,811 | Implemented |
KU0449 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,197 | $2,072 | Implemented |
KU0449 # 07 Y:1994 | 07 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $390 | $720 | Not Implemented |
KU0449 # 08 Y:1994 | 08 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,171 | $113 | Not Implemented |
KU0449 # 09 Y:1994 | 09 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $455 | $241 | Implemented |
ME0145 # 01 Y:1994 | 01 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,797 | $300 | Implemented |
ME0145 # 02 Y:1994 | 02 | 1994 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $1,471 | $800 | Not Implemented |
ME0145 # 03 Y:1994 | 03 | 1994 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $827 | $85 | Not Implemented |
ME0145 # 04 Y:1994 | 04 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $642 | $550 | Not Implemented |
OD0014 # 01 Y:1994 | 01 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $760 | $1,242 | Implemented |
OD0014 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,974 | $4,176 | Not Implemented |
OD0014 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,646 | $800 | Implemented |
OD0014 # 04 Y:1994 | 04 | 1994 | CONVERT COMBUSTION EQUIPMENT TO BURN OIL | $28,185 | $14,000 | Not Implemented |
OD0014 # 05 Y:1994 | 05 | 1994 | INSULATE BARE EQUIPMENT | $3,144 | $3,183 | Not Implemented |
OD0014 # 06 Y:1994 | 06 | 1994 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $5,709 | $975 | Implemented |
OD0014 # 07 Y:1994 | 07 | 1994 | METER WASTE WATER | $1,403 | $200 | Not Implemented |