Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,547
matching recommendationsSIC | 2653 | Corrugated And Solid Fiber Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
RU0098 # 03 Y:1990 | 03 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,134 | $302 | Not Implemented |
RU0098 # 04 Y:1990 | 04 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,244 | $0 | Implemented |
RU0098 # 05 Y:1990 | 05 | 1990 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,377 | $1,250 | Not Implemented |
RU0098 # 06 Y:1990 | 06 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,352 | $500 | Not Implemented |
RU0098 # 07 Y:1990 | 07 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,437 | $6,800 | Not Implemented |
RU0098 # 08 Y:1990 | 08 | 1990 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $7,333 | $13,400 | Not Implemented |
RU0098 # 09 Y:1990 | 09 | 1990 | REPAIR AND ELIMINATE STEAM LEAKS | $11,639 | $1,455 | Implemented |
UD0321 # 01 Y:1990 | 01 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,217 | $37,000 | Implemented |
UD0321 # 02 Y:1990 | 02 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,310 | $7,500 | Implemented |
UD0321 # 03 Y:1990 | 03 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,760 | $1,100 | Implemented |
UD0321 # 04 Y:1990 | 04 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,068 | $14,000 | Not Implemented |
WI0086 # 01 Y:1990 | 01 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $39,882 | $0 | Not Implemented |
WI0086 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,034 | $2,719 | Not Implemented |
WI0086 # 03 Y:1990 | 03 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,311 | $0 | Not Implemented |
WI0086 # 04 Y:1990 | 04 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,293 | $7,000 | Not Implemented |
WI0086 # 05 Y:1990 | 05 | 1990 | INSTALL STORM WINDOWS AND DOORS | $1,028 | $2,448 | Not Implemented |
WI0086 # 06 Y:1990 | 06 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $799 | $250 | Not Implemented |
WI0086 # 07 Y:1990 | 07 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $679 | $500 | Not Implemented |
WI0086 # 08 Y:1990 | 08 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $508 | $2,000 | Not Implemented |
RU0072 # 01 Y:1989 | 01 | 1989 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $34,166 | $0 | Not Implemented |
RU0072 # 02 Y:1989 | 02 | 1989 | IMPROVE LUBRICATION PRACTICES | $2,938 | $800 | Not Implemented |
RU0072 # 03 Y:1989 | 03 | 1989 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,681 | $6,660 | Not Implemented |
RU0072 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,696 | $416 | Implemented |
RU0072 # 05 Y:1989 | 05 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,337 | $2,400 | Implemented |
RU0072 # 06 Y:1989 | 06 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,923 | $400 | Implemented |