Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
13
matching recommendationsSIC | 2672 | Paper Coated And Laminated, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0003 # 01 Y:1991 | 01 | 1991 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $83,295 | $210,000 | Not Implemented |
IA0003 # 02 Y:1991 | 02 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,060 | $1,975 | Not Implemented |
IA0003 # 03 Y:1991 | 03 | 1991 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,902 | $0 | Not Implemented |
IA0003 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $128 | $0 | Not Implemented |
IA0003 # 05 Y:1991 | 05 | 1991 | INSTALL SET-BACK TIMERS | $326 | $400 | Not Implemented |
KU0348 # 01 Y:1991 | 01 | 1991 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $273,825 | $0 | Not Implemented |
KU0348 # 02 Y:1991 | 02 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $42,794 | $88,000 | Not Implemented |
KU0348 # 03 Y:1991 | 03 | 1991 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,004 | $0 | Not Implemented |
KU0348 # 04 Y:1991 | 04 | 1991 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $12,446 | $45,900 | Not Implemented |
KU0348 # 05 Y:1991 | 05 | 1991 | RECOVER AND REUSE COOLING WATER | $7,804 | $9,000 | Not Implemented |
KU0348 # 06 Y:1991 | 06 | 1991 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,697 | $3,200 | Not Implemented |
KU0348 # 07 Y:1991 | 07 | 1991 | INSTALL SET-BACK TIMERS | $522 | $200 | Not Implemented |
KU0348 # 08 Y:1991 | 08 | 1991 | INSTALL SET-BACK TIMERS | $193 | $282 | Not Implemented |